Page view 0
Operating and Installation
Instructions
Ventilation System
DA 5190 W
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 07 787 390
en - US, CA
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - DA 5190 W

Operating and InstallationInstructionsVentilation SystemDA 5190 WTo prevent accidentsand appliance damage,read these instructionsbeforeinstallation or

Page 2 - Contents

Turning on the fan^Press the On/Off button.Selecting the power level^ Use the "–/+" controls to select thedesired power level.+ = increases

Page 3

If the power level indicators "1" and "4"flash, the automatic switch back is notactivated.^To activate the automatic switch backpr

Page 4 - COOKTOP GREASE FIRE:

Delayed Shut DownIf odors or smoke remain in the kitchenafter cooking has been completed, theDelayed Shut Down feature can beselected to allow the hoo

Page 5

Turning the lighting on/offThe overhead lighting can be turned onand off independently of the fan.^Press the light button briefly to turnon the lighti

Page 6

Grease filter timerA timer monitors the hours of fanoperation. The indicator for thegrease/charcoal filter will light red after30 hours of operation o

Page 7 - Functional description

Reprogramming the grease filtertimerThe grease filter timer is preset to 30hours. This time can be lengthened orshortened to 20, 30, 40 or 50 hours.–A

Page 8

Reprogramming the charcoal filtertimerThe active charcoal filter can only beused in recirculation mode and cannotbe used to exhaust fumes.The charcoal

Page 9

,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before cleaning or servicing thehood, disconnect it from

Page 10 - Operation

Grease filterThe reusable metal grease filterremoves solid particles from the ventedkitchen air (grease, dust, etc).The grease filter should be cleane

Page 11

Cleaning the grease filter^By hand: use a scrub brush with asolution of warm water and milddetergent.Do not use pure detergent,aggressive all purpose

Page 12

IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Functional description . . . . . . . . . . . . . . . .

Page 13

Active charcoal filterIn recirculation mode an activecharcoal filter must be used in additionto the grease filter. The charcoal filter isdesigned to a

Page 14

Changing the light bulbs,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before changing the light bulbs,d

Page 15

RepairsIn the event of a fault which you cannoteasily fix yourself, please contact theMiele Technical Service Department.^When contacting the Technica

Page 16

Installation InstructionsRead these instructions and the "Important Safety Instructions" before installingthis hood.The installation steps a

Page 18

Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an

Page 19

1) Air extraction mode2) Recirculation mode3) Recirculation vent installed upwards4) and 5) Installation areaWall/ceiling area respectively for ventho

Page 20

4) and 5)Cut-out area in wall or ceiling forentrance of 6" (150 mm)ductwork or 5" (125 mm) ductwork witha reducing collar.The installation p

Page 21

Distance between cooktop and hood (S)Do not install this exhaust hood over cooktops burning solid fuel.Provided a larger distance is not given by the

Page 22 - After Sales Service

The majority of the weight of theinstalled ventilation system will besupported by the lower retainingplate. It must be firmly attached tothe stud fram

Page 23 - Installation Instructions

READ AND SAVE THESEINSTRUCTIONSKeep these instructions in a safeplace and pass them on to any futureuser.Read these instructions carefullybefore insta

Page 24

Installation30

Page 25 - Caring for the environment

a 3 protective shieldsto prevent scratches to the chimneyduring installation.b 1 vent collarfor use with 6" (150 mm) exhaustductingc 1 reducing c

Page 26 - Appliance dimensions

Protective filmThe casing is covered with a protectivefilm to prevent scratching duringtransport.^Peel off the film before installing thecasing parts.

Page 27

,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk of fire and topr

Page 28

– If the exhaust is ducted into aninactive flue, the air must be expelledparallel to the flow direction of theflue.Never connect an exhaust hood toan

Page 29 - Plywood backing

,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:All electrical work should beperformed by a qualified ele

Page 30 - Installation

Maximum load ...430WFan...350WOverhead lighting ...4x20WVoltage ...120VFrequency ...

Page 34

~d) Before connecting the applianceto the power supply make sure that thevoltage and frequency listed on thedata plate correspond with thehousehold el

Page 35 - Electrical connection

Alteration rights reserved / 0610INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOSTCURRENT PRODUCT SPECIFICATIONS, TECHN

Page 36 - Technical data

,WARNINGTO REDUCE THE RISK OFINJURY TO PERSONS IN THEEVENT OF A COOKTOPGREASE FIRE, OBSERVE THEFOLLOWING*:~a) SMOTHER FLAMES with a closefitting lid,

Page 37

Installation,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:~a) Installation work and electricalwiring mu

Page 38

The ventilation hood offers two modes of operation:Air extractionThe air is drawn in and cleaned by thegrease filter and directed outside.The hood com

Page 39

Guide to the Ventilation System8

Page 40 - M.-Nr. 07 787 390 / 01

a Chimney extensionb Chimneyc Canopyd Overhead lightinge Recirculation vent(only in recirculation mode)f Active Charcoal FilterAvailable to purchase,