Operating and Installation
Instructions
Ventilation System
DA 289-4
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 07 782 280
en-US
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - DA 289-4

Operating and InstallationInstructionsVentilation SystemDA 289-4To prevent accidentsand appliance damage,read these instructionsbeforeinstallation or

Page 2 - Contents

Turning on the fan^Press the On/Off button.Selecting the power level^Use the "–/+" controls to select thedesired power level.+ = increases t

Page 3

If the power level indicators "1" and "4"flash the automatic switch back is notactivated.^To activate the automatic switch backpre

Page 4 - COOKTOP GREASE FIRE:

Delayed Shut DownIf odors or smoke remain in the kitchenafter cooking has been completed, theDelayed Shut Down feature can beselected to allow the hoo

Page 5

Turning the lighting on/offThe overhead lighting can be turned onand off independently of the fan.^Press the light button briefly to turnon the lighti

Page 6

Grease filter timerA timer monitors the hours of fanoperation. The indicator for the greasefilter will light after 30 hours ofoperation. The grease fi

Page 7 - Functional description

Reprogramming the grease filtertimerThe grease filter timer is preset to 30hours. This time can be lengthened orshortened to 20, 30, 40 or 50 hours.–A

Page 8

If the indicator light for the grease filterturns blue during operation, thisindicates that an unrequired electronichas been activated.To deactivate:–

Page 9

,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before cleaning or servicing thehood, disconnect it from

Page 10 - Operation

Grease filter and air intakepanelThe reusable metal grease filterremoves solid particles from the ventedkitchen air (grease, dust, etc).The grease fil

Page 11

Cleaning the grease filters^By hand: use a scrub brush with asolution of warm water and milddetergent.Do not use the pure detergent,aggressive all pur

Page 12

IMPORTANT SAFETY INSTRUCTIONSFunctional descriptionGuide to the Ventilation SystemOperationTurning on the fan ...

Page 13

Changing the light bulb,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before changing the light bulbs,di

Page 14

RepairsIn the event of a fault which you cannoteasily fix yourself, please contact theMiele Technical Service Department.^When contacting the Technica

Page 16

Installation InstructionsRead these instructions and the "Important Safety Instructions" before installingthis ventilation system.The instal

Page 18

Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an

Page 19

Appliance dimensions26

Page 20

1) and 2)Cut out area in wall or ceiling forentrance of 6" (150 mm)ductwork or 5" (125 mm) ductwork witha reducing collar.Do not install thi

Page 21 - After Sales Service

Installation accessories28

Page 22

a 3 protective shieldsprevent scratches to the chimneyduring installation.b Upper retaining plate secures thechimney extension.c Middle retaining plat

Page 23 - Installation Instructions

READ AND SAVE THESEINSTRUCTIONSKeep these instructions in a safeplace and pass them on to any futureuser.Read these instructions carefullybefore insta

Page 24

The majority of the weight of theinstalled ventilation system will besupported by the lower retainingplate. It must be firmly attached tothe stud fram

Page 25 - Caring for the environment

Protective filmThe casing is covered with a protectivefilm to prevent scratching duringtransport.^Peel off the film before installing thecasing parts.

Page 26 - Appliance dimensions

,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk of fire and topr

Page 27

– If the exhaust is ducted into aninactive flue, the air must be expelledparallel to the flow direction of theflue.Never connect an exhaust hood toan

Page 28 - Installation accessories

,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:All electrical work should beperformed by a qualified ele

Page 30 - Plywood backing

Alteration rights reserved / 2011INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOSTCURRENT PRODUCT SPECIFICATIONS, TECHN

Page 31 - Installation

~d) Before connecting the applianceto the power supply make sure that thevoltage and frequency listed on thedata plate correspond with thehousehold el

Page 32 - Air extraction

,WARNINGTO REDUCE THE RISK OFINJURY TO PERSONS IN THEEVENT OF A COOKTOPGREASE FIRE, OBSERVE THEFOLLOWING*:~a) SMOTHER FLAMES with a closefitting lid,

Page 33

Installation,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:~a) Installation work and electricalwiring mu

Page 34 - Electrical connection

The ventilation hood works by airextraction. The air is drawn in andcleaned by the grease filter anddirected outside.The hood comes equipped with anon

Page 35

Guide to the Ventilation System8

Page 36 - M.-Nr. 07 782 280 / 01

a Chimney extensionb Chimneyc Canopyd Control panele Overhead lightingf Grease filterg Air intake panelh Light buttonThis button dims the light or tur