Operating and Installation instructionsRangehoodTo avoid the risk of accidents or damage to the appliance, it is essentialto read these instructions b
Operation10
a Controlsb Cooktop lightingc Charcoal filterSpecial accessory for recirculationmoded Cover for the charcoal filter ducte Grease filtersf Exhaust sock
,Before any cleaning ormaintenance work is carried out,disconnect the rangehood from themains supply. Ensure that– it is switched off at the wall sock
Important for appliances withlacquered housingIt is very difficult to clean this type ofsurface without causing minor marks tothe surface material.Thi
Cleaning the grease filters by hand^Clean the filter with a soft nylon brushin a mild solution of hot water and alittle washing-up liquid.Do not use u
Charcoal filterIf the rangehood is connected forrecirculation (see "Installation"), a MieleNoSmell active charcoal filter must beinserted in
Changing a halogen lamp^Ensure the rangehood isdisconnected from the electricitysupply. To do this:–switch off at the wall socket andremove the plug,
In the event of a fault which you cannotcorrect yourself, or if the appliance isunder guarantee, please contact:–your Miele Chartered Agentor–MieleYou
DA 1050-55 ...B=548mmDA 1060, DA 1160 ...B=598mmDA 1100 ...B=998mmExhaust connectionC 150 mm or C 125 mm.If the rangehood is
Safety distance between cooktop andrangehoodThe minimum distances betweenthe top of a cooktop and the bottomof the rangehood are as follows,unless a g
Caring for the environment...3Warning and Safety instructions ...4Description
Before installation, it is important toread the information given on the"Warning and Safety instructions" atthe beginning of this booklet.Th
^For operation in recirculation mode,cover the opening at the back of therangehood with the sticker suppliedwith the NoSmell active charcoal filter(op
^For extraction mode, you must alsocut out a 170 mm diameter hole inthe bottom of the wall unit.^If the mains connection cable is to befed through the
^Fix the mounting plates to the wallusing the plugs and screws supplied.,The screws and plugs aredesigned for use in solid walls only.For other types
^Hang the rangehood on the mountingplates.^Tighten the screws at the back of therangehood on the left and right. Thiswill adjust the pitch of the rang
^ Attach the exhaust ducting to theexhaust socket, for example using aflexible exhaust hose and a hose clip(optional accessory).^ Insert the exhaust s
All electrical work should beundertaken by a suitably qualifiedand competent person in strictaccordance with current nationaland local safety regulati
Important: To avoid the danger oftoxic fumes, please observe theWarning and Safety instructions.This is especially crucial when usingthe rangehood at
Condensate trap(optional accessory)In addition to insulating the exhaustducting, we recommend that a suitablecondensate trap is installed to collectan
DA 1050-55, DA 1060Total rated load ...300WFan motor...2x100WCooktop lighting ...2x50WVoltage ... AC230VFr
Disposal of the packingmaterialThe transport and protective packinghas been selected from materials whichare environmentally friendly for disposaland
30
31
M.-Nr. 09 712 770 / 01en - AU, NZDA 1050-55DA 1060DA 1160DA 1100
This appliance complies with allrelevant local and national safetyrequirements. Inappropriate usecan, however, lead to personalinjury and damage to pr
Technical safety~Before installation, check therangehood for visible signs of damage.Under no circumstances should youuse a damaged appliance. A damag
~Do not connect the appliance to themains electricity supply by amulti-socket unit or an extension lead.These do not guarantee the requiredsafety of t
There must be adequate ventilation ofthe room when the rangehood is usedat the same time as appliances burninggas or other fuels.In order to ensure sa
~Do not use the rangehood withoutthe filters in place. This way you willavoid the risk of grease and dirt gettinginto the appliance and hindering itss
The rangehood works with. . . air extraction:The air is drawn in and cleaned by thegrease filters and directed outside.If the on-site ventilation syst