Miele DA 402 User Manual

Browse online or download User Manual for Cooker hoods Miele DA 402. Miele DA 402 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Operating and Installation
Instructions
Ventilation System
DA 402
To prevent accidents
and machine damage,
read these instructions
before
installation or use.
UV
M.-Nr. 06 473 980
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - Ventilation System

Operating and InstallationInstructionsVentilation SystemDA 402To prevent accidentsand machine damage,read these instructionsbeforeinstallation or use.

Page 2 - Contents

Turning on the fan^Press the On/Off button.Selecting the power level^Use the "– / +" controls to select thedesired power level.& = incre

Page 3 - IMPORTANT SAFETY INSTRUCTIONS

If the power level indicators flash theautomatic switch back is not activated.^To activate the automatic switchpress the "+" button.The powe

Page 4

Delayed Shut DownIf odors or smoke remain in the kitchenafter cooking has been completed, theDelayed Shut Down feature can beselected to allow the hoo

Page 5

Turning the lighting on/offThe overhead lighting can be turned onand off independently from the fan.^Press the light button briefly to turnon the ligh

Page 6

Filter timersA timer monitors the hours of fanoperation. The indicator for the greasefilter will light after 30 hours ofoperation. The grease filters

Page 7 - Functional description

Reprogramming the timersThe grease filter timer is preset to 30hours. This time can be lengthened orshortened to 20, 30, 40, or 50 hours.–A time of 20

Page 8 - Guide to the appliance

Before cleaning or servicing thehood, disconnect it from the powersupply by either removing the fuse,unplugging it from the outlet, ormanually "t

Page 9

Grease filtersThe reusable metal grease filtersremove solid particles from the ventedkitchen air (grease, dust, etc).The grease filters should be clea

Page 10 - Operation

Changing the light bulbBefore changing the light bulbs,disconnect the hood from the powersupply by either removing the fuse,unplugging it, or manually

Page 11

In the event of a fault which you cannotcorrect yourself please contact theMiele Technical Service Department :U [email protected]

Page 12

IMPORTANT SAFETY INSTRUCTIONSFunctional descriptionGuide to the applianceOperationTurning on the fan . . . . . . . . . . . . . . . . . . . . . . . . .

Page 14

Installation Instructions

Page 16 - Cleaning and Care

Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an

Page 17

Installation accessories24

Page 18

a 3 protective shields to preventscratches to the chimney duringinstallation.b 2 hose clips for securing theducting.c 1 reducing collar for use with 5

Page 19 - After Sales Service

The majority of the weight of theinstalled ventilation system will besupported by the lower retainingplate. It must be firmly attached tothe stud fram

Page 20

All electrical work should beperformed by a qualified electricianin strict accordance with nationaland local safety regulations.Installation, repairs

Page 21 - Installation Instructions

1) and 2) Installation areaWall/ceiling area respectively for venthole and outlet installation.Vent hole 57/8" (150 mm) with reducingcollar 5&quo

Page 22

Do not install this exhaust hood overcooktops burning solid fuel.When installing the hood, make surethat the following minimumdistance (S) between the

Page 23 - Caring for the environment

Read these Operating Instructions carefully before installing orusing the Ventilation System.This appliance is intended forresidential use only. Use t

Page 24 - Installation accessories

Installation instructionsSee the enclosed installation instructionsheet.Please read the "Important SafetyInstructions" and Installationinstr

Page 25

,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.The exhaust gases extracted bythe h

Page 26 - Plywood backing

If the exhaust is ducted into an inactiveflue, the air must be expelled parallel tothe flow direction of the flue.Never connect an exhaust hood toan a

Page 30 - Installation

M.-Nr. 06 473 980 / 00-Alteration rights reserved / 0805

Page 31 - Air extraction

This equipment is not designed formaritime use or for use in mobileinstallations such as recreationalvehicles or aircraft. However, undercertain condi

Page 32

, WARNING - TO REDUCETHE RISK OF A COOKTOPGREASE FIRE:Never leave surface unitsunattended at high settings.Boilovers cause smoking and greasyspillover

Page 33

Installation, WARNINGTo reduce the risk of fire onlyuse metal ductwork.When installing the hood, follow therecommended minimum safetydistances between

Page 34

The ventilation hood works by airextraction. The air is drawn in andcleaned by the grease filters anddirected outside.The hood comes equipped with ano

Page 35

Guide to the appliance8abcfdekghijdai1664ns– +515mns– +515m|l

Page 36 - M.-Nr. 06 473 980 / 00

a Chimney extensionb Chimneyc Canopyd Control panele Grease filterf Overhead lightingg Light buttonThis button turns the light on and offand also dims

Comments to this Manuals

No comments