Operating and InstallationInstructionsVentilation SystemDA 5000 DTo prevent accidentsand appliance damage,read these instructionsbeforeinstallation or
Turning on the fan s^Touch the "s" sensor button.The fan switches on to level "2".The sensor buttons "s" and "2&quo
Delayed shut down "5m15"If odors or smoke remain in the kitchenafter cooking has been completed, theDelayed Shut Down feature can beselected
Indirect lightingTouch the " " sensor button to turn theindirect lighting On/Off.Safety cut-offIf the exhaust hood is left unattendedfor mor
Reprogramming the grease filtertimerThe grease filter timer is preset to 30hours. This time can be lengthened orshortened to 20, 30, 40, or 50 hoursde
,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before cleaning or servicing thehood, disconnect it from
Grease filtersThe reusable metal grease filtersremove solid particles from the ventedkitchen air (grease, dust, etc) and helpkeep the exhaust hood cle
Depending on the detergent,cleaning the grease filters in adishwasher may cause permanentdiscoloration of the filter surface.Performance of the filter
Changing the halogen lightbulbsTo change the halogen bulbs, first openthe canopy.^Touch the "s" sensor button.The fan turns on to level &quo
Changing the fluorescent lightbulbDisconnect the exhaust hood fromthe power supply by either removingthe fuse, unplugging it, or manually"trippin
RepairsIn the event of a fault which you cannoteasily fix yourself, please contact theMiele Technical Service Department.^When contacting Technical Se
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Functional description . . . . . . . . . . . . . . . .
20
Installation InstructionsRead these instructions and the "Important Safety Instructions" before installingthis ventilation system.The instal
22
Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an
1) Feed-though for the duct work andthe power cordExhaust connection C 77/8" (200 mm)The exhaust connection is adjustable.This makes installation
Distance between cooktop and hood (S)Do not install this exhaust hood over cooktops burning solid fuel.Provided a larger distance is not given by the
The ceiling mounting plate willsupport the weight of the hood. Thisceiling plate must be attached torigid structural framing that issupported in its e
Protective filmThe casing is covered with a protectivefilm to prevent scratching duringtransport.^Peel off the film before installing thecasing parts.
,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk of fire and topr
If the exhaust is ducted into an inactiveflue, the air must be expelled parallel tothe flow direction of the flue.Never connect an exhaust hood toan a
READ AND SAVE THESEINSTRUCTIONSKeep these instructions in a safeplace and pass them on to any futureuser.Read these instructions carefullybefore insta
,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:All electrical work should beperformed by a qualified ele
Total connected load...772W– fan motor...640W– canopy drive...4W– direct lighting ...2x50W– indirect ligh
Alteration rights reserved / 1711INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOSTCURRENT PRODUCT SPECIFICATIONS, TECHN
~d) Before connecting the applianceto the power supply make sure that thevoltage and frequency listed on thedata plate correspond with thehousehold el
,WARNINGTO REDUCE THE RISK OFINJURY TO PERSONS IN THEEVENT OF A COOKTOPGREASE FIRE, OBSERVE THEFOLLOWING*:~a) SMOTHER FLAMES with a closefitting lid,
Installation,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:~a) Installation work and electricalwiring mu
The ventilation hood works by airextraction. The air is drawn in andcleaned by the grease filter anddirected outside.The hood comes equipped with anon
Guide to the Ventilation System8
a Covering frameb Chimneyc CanopyThe canopy opens as soon as the fan isturned on.d Indirect lightinge Control panelThe symbols serve as sensor buttons