Operating and installation instructionsVentilation SystemDA 251DA 252-3DA 259-3To prevent accidentsand machine damage,read these instructionsbeforeins
Turning on the fan^Press the On/Off button.The fan runs at power level "2".The On/Off indicator lights.Selecting the power level^ Use the _
Turning off the fan^Press the On/Off button to turn thefan off.The indicator goes out.Automatic Safety Shut OffThe fan will be turned off automaticall
Grease filter timerA timer monitors the hours of fanoperation. The indicator for the greasefilter will light after 30 hours ofoperation. The grease fi
Reprogramming the grease filtertimerThe grease filter timer is preset to 30hours. This time can be lengthened orshortened to 20, 30, 40 or 50 hours.–A
Before cleaning or servicing thehood, disconnect it from the powersupply by either removing the fuse,unplugging it from the outlet ormanually "tr
Grease filtersThe reusable metal grease filtersremove solid particles from the ventedkitchen air (grease, dust, etc).The grease filters should be clea
Changing the light bulbsBefore changing the light bulbs,disconnect the hood from the powersupply by either removing the fuse,unplugging it, or manuall
In the event of a fault which you can notcorrect yourself please contact:–Your Miele Dealeror–The Miele Technical ServiceDepartmentUSA 1-800-999-1360t
Installation Instructions
IMPORTANT SAFETY INSTRUCTIONSFunctional descriptionGuide to the applianceOperationTurning on the fan . . . . . . . . . . . . . . . . . . . . . . . . .
Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an
The majority of the weight of theinstalled ventilation system will besupported by the canopy. Itsmounting bracket must be firmlyattached to the stud f
Installation accessories22
a 2 protective shieldsprevent scratches to the chimneyduring installation.b 2 hose clips for securing theexhaust ducting.c 1 reducing collarfor use wi
All electrical work should beperformed by a qualified electricianin strict accordance with nationaland local safety regulations.Installation, repairs
Cut out area in wall or ceiling forentrance of 6" (150 mm)ductwork or 5" (125 mm)ductwork with a reducing collar.Do not install this hood ov
If the standard unit height H is notsuitable to the kitchen’s ceiling height,longer optional chimney extensions areavailable from your Miele dealer or
,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.The exhaust gases extracted bythe h
– If the exhaust is ducted into aninactive flue, the air must be expelledparallel to the flow direction of theflue.Never connect an exhaust hood toan
Read these Operating Instructions carefully before installing orusing the Ventilation System.This appliance is intended forresidential use only. Use t
31
M.-Nr. 05 802 960 / 01Alteration rights reserved / 1503This bio-friendly paper was bleached without the use of chlorine.
This equipment is not designed formaritime use or for use in mobileinstallations such as caravans oraircraft. However, under certainconditions it may
, WARNING - TO REDUCETHE RISK OF A RANGE TOPGREASE FIRE:Never leave surface unitsunattended at high settings.Boilovers cause smoking and greasyspillov
Installation, WARNINGTo reduce the risk of fire onlyuse metal ductwork.When installing the hood, follow therecommended minimum safetydistances between
The ventilation hood works by airextraction. The air is drawn in andcleaned by the grease filters anddirected outside.The hood comes equipped with ano
Guide to the appliance8
a Chimney extensionb Chimneyc Canopyd Grease filtere Overhead lightingf Indirect lightingg Glass shelvesEach holds up to 8 lbs.h Canopy storage surfac
Comments to this Manuals