Installation instructions
This appliance is classified as ”Y“ class
for heat protection. There may be a wall
at the rear and a wall or tall cabinet at
one side. On the other side, however,
no cabinet or wall must stand higher
than the grill.
There must be a minimum distance
of 9-7/8" (250 mm) between the ap-
pliance and adjacent cabinetry, be-
cause of the heat radiated from the
elements.
Prepare the countertop cut-out as il-
lustrated.
Dimension ”B“ will vary depending on
how many combisets are installed.
The following chart gives dimension
”B“ for a variety of 2 zone (ie KM 88-2)
and 4 zone (ie KM 93-2) combinations.
Depth
in
mm
Width *
(= Dimen-
sion B)
in mm
2 zone Combiset
1 Combiset
2 Combisets
3 Combisets
4 Combisets
5 Combisets
490
490
490
490
490
265
558
851
1144
1437
4 zone Combiset
1 Combiset
2 Combisets
3 Combisets
490
490
490
560
1143
1728
Combination
One 2 zone
+ one 4 zone
Two 2 zone
+ one 4 zone
Three 2 zone
+ one 4 zone
One 2 zone
+ two 4 zone
Two 2 zone
+ two 4 zone
490
490
490
490
490
851
1143
1437
1436
1729
Extractor (e.g. DA 8-2)
For building in between two
appliances:
- Dimension B increases by 90 mm.
For building in at the end of a
combination:
- Dimension B increases by 98 mm.
* Width includes provision for V 98 spacer bar.
2-3/16"
19-5/16"
2-3/16"’
Installation instructions