Page view 9
Controls · Programmes · Durations
Fully electronic controls, reliable
processing
The MULTITRONIC controls on Miele
washer disinfectors precisely monitor and
control programmes and functions. Miele
washer disinfectors are equipped with
an RS 232 serial interface which can be
used to transfer data to a report printer
or PC. Important disinfection programme
data including programme duration,
temperatures and any faults or user
interventions are included in the report.
Simple operation
All symbols used on the control panel are
language neutral and self-explanatory.
Programme sequence indictor lights keep
the user informed on progress. A 3 digit,
7 segment display shows programme
durations as well as wash and disinfection
temperatures. Status and control check
lights are used to alert the user to
maintenance requirements and possible
faults.
Powerful, yet energy-efficient
performance
Miele washer disinfectors have a large
wash cabinet with two cleaning levels
(upper and lower baskets) and can be
used to process instruments, accessories,
trays and containers. The upper basket
connects directly to the water inlet and
a flow wheel monitors the water intake.
By using just the right amount of water
for each programme and controlling the
amount of detergent used operating costs
are also kept to a minimum.
Thorough cleaning, assured disinfection
Standardised procedures are used for
machine processing instruments.
The vario TD programme consists of
a pre-wash at low temperature so that
blood deposits are not denatured. This
is followed by an intensive main wash
including thermal disinfection at >90°C
with a 5 minute holding time.
For optimum care of surgical instruments
the final rinse should be carried out with
dimeneralised water and without using
rinsing agent. This programme is suitable
for the routine processing of all thermally
stable instruments in accordance with
EN ISO 15883. It is also ideal for
processing transmission instruments as
it treats materials with care. The G 7891
has an integrated hot air drying unit for the
thorough drying of all types of instruments.
The SPECIAL 93°C-10’ programme
complies with the standards required for
the containing of epidemics in disinfectors
and decontamination units, according to
§ 18 of IfSG (German infection protection
regulations). The Robert Koch Institute
in Berlin (German institute for infectious
diseases and non-communicable illnesses)
has declared this programme to be
suitable in effective areas A and B for the
destruction of vegetative bacteria including
mycro-bacteria, fungi and fungal spores
and also for inactivating viruses, including
HBV and HIV.
Illustration shows G 7881