Operating and installation instructions
Ventilation System
DA 229-2
To prevent accidents
V
and machine damage,
read these instructions
before installation or use. M.-Nr. 05 603 730
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - DA 229-2

Operating and installation instructionsVentilation SystemDA 229-2To prevent accidentsVand machine damage,read these instructionsbefore installation or

Page 2 - Table of Contents

Turning off the fan^Press the On/Off button to turn thefan off.The indicator goes out.Automatic Safety Shut OffThe fan will be turned off automaticall

Page 3 - PERIODICALLY

Grease filter timerA timer monitors the hours of fan opera-tion. The indicator for the grease filterwill light after 30 hours of operation. Thegrease

Page 4

Reprogramming the grease filtertimerThe grease filter timer is preset to 30hours. This time can be lengthened orshortened to 20, 30, 40 or 50 hours.–A

Page 5

Before cleaning or servicing thehood, disconnect it from the powersupply by either removing the fuse,unplugging it from the outlet or man-ually "

Page 6 - Guide to the appliance

Grease filtersThe reusable metal grease filters re-move solid particles from the ventedkitchen air (grease, dust, etc).The grease filters should be cl

Page 7

When putting the grease filters backmake sure that the locking clips are vis-ible facing down towards the cookingsurface.If a filter is incorrectly in

Page 8 - Functional description

Changing the light bulbBefore changing the light bulbs, dis-connect the hood from the powersupply by either removing the fuse,unplugging it, or manual

Page 9

In the event of a fault which you cannotcorrect yourself please contact:–Your Miele Dealeror–The Miele Technical ServiceDepartmentUSA 1-800-999-1360te

Page 11

Installation instructions

Page 12

Warning and Safety instructionsGuide to the applianceFunctional descriptionOperationMain power switch . . . . . . . . . . . . . . . . . . . . . . . .

Page 13 - Cleaning and Care

Caring for the environmentInstallation accessoriesPlywood backingElectrical dataAppliance dimensionsInstallationRetaining plates . . . . . . . . . . .

Page 14

Disposal of packing materialThe cardboard box and packing materi-als protect the appliance during ship-ping. They have been designed to bebiodegradab

Page 15

Installation accessories22

Page 16

a 2 protective shieldsprevent scratches to the chimney dur-ing installation.b 2 hose clips for securing theducting.c 1 reducing collarfor use with 5&q

Page 17 - After Sales Service

The majority of the weight of the in-stalled ventilation system will besupported by retaining plate A. Itmust be firmly attached to the studframing be

Page 18

All electrical work should be per-formed by a qualified electrician instrict accordance with national andlocal safety regulations.Installation, repair

Page 20

Do not install this exhaust hood overcooktops burning solid fuel.When installing the hood, make surethat the following minimum dis-tance (S) between t

Page 21 - Caring for the environment

Retaining platesThe ventilation system will be mounted tothe wall through the use of retainingplates. Plate A is installed first, followedby plate B.

Page 22 - Installation accessories

Retaining plate A^Drill two1/8" (3 mm) holes, one at S +3" (75 mm) and one at S + 153/4"(400 mm) on the center line (see "Ap-plian

Page 23

Read these Operating Instructions carefully before installing orusing the Ventilation System.This appliance is intended for resi-dential use only. Use

Page 24 - Plywood backing

Retaining plate B^Hold retaining plate B to the wall andpush up until it is directly below theceiling. Use the notches and the cen-ter line to align i

Page 25 - Electrical data

Attaching the canopy^ Hang the canopy on the angledbrackets on retaining plate A.^ Secure the canopy with two screws5 x 60 mm.Adjusting the canopyIf t

Page 26 - Appliance dimensions

Inserting the non-return flap^If a non-return flap is not present inthe venting system, the non-returnflap supplied must be fitted into theexhaust con

Page 27

Electrical connectionBefore connecting the applianceread the "Warning and Safety In-structions" and the "Electrical data"sections.

Page 28 - Installation

Attaching the chimneyextensionThe use of a chimney extension, allowsthe hood to be installed at various dis-tances from the ceiling.^Remove the protec

Page 29

Attaching the chimney^ Remove the protective foil from thechimney.^ Pull the chimney apart slightlyandslide it over the chimney extension.Do this care

Page 30

Danger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can be harm-ful or fatal if inhaled. The exhaustgases extracted by the hoodsh

Page 31

Never connect an exhaust hood toan active chimney, dryer vent, ventflue, or room venting ductwork. Seekprofessional advice before connect-ing an exhau

Page 34

This equipment is not designed formaritime use or for use in mobileinstallations such as caravans or air-craft. However, under certain conditionsit ma

Page 35

Alteration rights reserved / 000 CDN - 1801This paper consists of cellulose which has been bleached without the use of chlorine.

Page 36 - Air extraction

Do not use an extension cord toconnect the appliance to electricity.Extension cords do not guarantee therequired safety of the appliance, (e.g.danger

Page 37

Guide to the appliance6

Page 38

Chimney extensionChimneyCanopyOverhead lightingMain power switchGrease filterGrease filter buttonThe indicator below the grease filterbutton lights wh

Page 39

The ventilation hood works by air ex-traction. The air is drawn in andcleaned by the grease filters and di-rected outside.The hood comes equipped with

Page 40

Main power switchPress the main power switch to "I". Thefan and the lighting can now be oper-ated.If the appliance is not going to be usedfo