1Vision T9800HRT Service Manual
10T9800(TM87) MCB WIRING(FOR 110V / 220V)P7P1P6J1P4 J2 P3 P7-------Motor wire P6------ on/off switch (power) J2-------Console cable P1-------Fan p
11T9800(TM87) MCB WIRING DEFINITION OF PIN JP1:Elevation cable(6pin/AMP-350762-4)Incline motor does turn on powerCOM6Incline motor does move to downDO
12J2: console cable121920ERR. SIG.19DefinitionPinConsole ground20RX IN(RESERVE)18RESERVE17TX OUT(RESERVE)16E_STOP15Console provide for incline motor
13T9800(TM87) CONSOLE WIRING J15 J13-------Safety Pull Switch J11-------Safety Push Switch J5---------Main HR Interface J14-------Console cable J
14T8900(TM87) CONSOLE WIRING DEFINITION OF PIN J14:20-pin console cable122019J14ERR. SIG.19DefinitionPinConsole ground20RX IN(RESERVE)18RESERVE17TX OU
15DefinitionNamePinConsole groundSS IN2Safe keySS OUT1J11: Safety Push SwitchJ13: Safety Pull SwitchJ13 J111212DefinitionNamePinConsole groundSS IN2Sa
16T9800(TM87) Electrical block diagram for 110V
17T9800(TM87) WIRING DIAGRAM INSTRUCTION for 110V
18T9800(TM87) Electrical block diagram for 220V
19T9800(TM87) WIRING DIAGRAM INSTRUCTION for 220V
2TABLE OF CONTENTSSECTION 1: MAINTENANCE PROCEDURE …………………31. MAINTENANCE CHECK LIST………………………...4 2. TENSIONING THE BELT
20SECTION 3CONSOLE FUNCTIONAL FLOW DIAGRAM
21OPERATING T9800
22To Store up the parameter SELECTDecrease this show parameter of speedSLOWAdd this show parameter of speedFASTTo scroll through the list of setting D
23SOFTWARE VERSION EXIT MAINTENANCE MANUAL CALIBRATION AUTO-CALIBRATION SYSTEM TESTSCONFIGURATION Engineering Mode Menu991540P27 DEFAULT AGE10:000:050
2467.8P20 EFF DIAMETER48126P19 MAGNET COUNTYESP13 ELV DIRECTION712740Value at zero or minimum elevationP4 ELEVATION MINMANUAL CALIBRATIONExits modeEXI
25ELEVATION BURN-IN TESTBURN-IN TESTEXITIO TESTSAFETY SWITCH TESTKEYBOARD TESTDISPLAY TESTHARDWARE TESTSYSTEM TESTS67.8 341P20 EFF DIAMETER48126P19
260ERROR LOG0TREADMILL MSG0P17 CLEAN0P26 LIFT MOTOR HOURSMAINTENANCEExits modeEXITOFFP16 LUBRICATE DECK MSG0P25 BELT/MOTOR HOURS6533500P10 TOTAL DIST
27SECTION 4MCB LED INSTRUCTIONS
28AC FAN
29Indicates if Console is commanding speed. LED 11PWMIndicates the motor is moving via the encoder's feedback by blinking. LED 12SPEEDIndicates i
3SECTION 1MAINTENANCE PROCEDURE
30SECTION 5TROUBLESHOOTINGS
31T9800 Console Error code NOVRAM failureE19Safety Switch Test FailureE18Stuck key errorE16Speed Range (usually caused by calibration)E9Speed stall (c
32E1 - Reverse Elevation Pot Error 1Enter engineer mode of “MANUAL CALIBRATION”screen Check the “P13 ELV DIRECTION” screen whether set to “Yes”Set to
33E2 – Elevation Out Of Range Error 2Step 1. Calibrate ElevationCalibrate the elevation as outlined in the System Calibration Procedure in below step.
34E3 – Elevation Stall NYNNYYE3 ErrorEnter Hardware Test ScreenRun Elevation Up And DownTreadmill moves up or down?Waiting the Elevation Motor to cool
35E5 – Over-speed Error Step 1. AUTO CALIBRATION AUTO-Calibration the as outlined in the System Calibration Procedure in below step. OVERVIEWIf the a
36E6 – Runaway Belt Error OVERVIEWIf the actual belt speed is greater than the target speed by a limit and increasing then an E6 error is called. E6
37E7 – Speed Stall Error OVERVIEWIf no belt movement is detected several seconds after commanding belt movement a speed stall error (E7) is called. NN
38E9 – Speed Range Error OVERVIEWDuring normal run time operation the value stored during auto calibration is used to initially set the speed (e.g. ta
39Speed Feedback Issues – See speed feedback issue trouble shooting section in the CORRECTIVE ACTION PROCEDURES – Speed Issues section of this documen
4MAINTENANCE CHECK LISTCleanMotorClean (Vacuum)Control BoardInspectRunning BeltInspect & Re-waxingDeck Re-waxingInspectCleanV BeltInspectRunning b
40CORRECTIVE ACTION PROCEDURES – Speed Issues Speed Feedback IssueEnter Magnet Count screen Magnet count = treadmill # of magnetsAdjust magnet count t
41Belt Drive IssueStart PWM max test (firmware setup screens), wait 20 seconds Perform steps in order listed until problem resolved.1..Replace ribbon
42Speed Control IssueStart PWM max test (firmware setup screens), wait 20 seconds or until speed stabilizesNYProblem FixedRun Auto Calibration (firmwa
43Speed Calibration IssueRun auto calibration (firmware setup screen)NYAuto calibration passedDoneStart PWM max test (firmware setup screen), wait min
44E19 – NOVRAM Failure OVERVIEWIf the values stored in non-volatile memory are out of limits or do not match the safety check value stored in non-vola
5TENSIONING THE BELT PROCEDURECaution:Over-tightening of the roller will severely shorten the life of the belt and may cause further damage to other c
6Drive Belt:If you have tensioned the running belt and are still experiencing a slipping, adjust the tension screw. Then try the treadmill again to c
7DECK RE-WAXING PROCEDUREFrequency: Every 1 monthParts name: Silicon oil setParts number: SZTM74SOSPrice (USD): 0.6Use time : 1Procedure:1. Loosen
8CLEAN THE GROOVES PROCEDUREFrequency: Every 3 monthsProcedure:1.Remove the drive belt and check the grooves in belt for dirt or dust and clean it. 3
9SECTION 2WIRING DIAGRAM INSTRUCTION
Comments to this Manuals