2.3 Heater control
Safety function:
If the NTC temperature sensor drying air (1R30) is defective, the heater is not
switched on.
The heater is switched off as soon as the heater relay is activated for more than 5
seconds without the motor relay being activated.
Heater reactivation is delayed by 10 s, the auxiliary heater is switched off before,
during and after a reversing pause.
2.4 Temperature limiter with manual reset (1F1, 2F1, 3F1)
T 9800
Three closed 3/4 inch temperature limiters, with manual reset via pushbutton, are
on the heater bank.
2.5 NTC temperature sensor drying air (1R30)
If the temperature sensor drying air NTC detects temperatures lower than 5°F (-
15°C) or higher than 320°F (160 °C), the NTC must be considered defective.
2.6 NTC temperature sensor heating/drying (2R30)
An open circuit in the NTC temperature sensor heating/drying (2R30) can only be
detected at temperatures higher than 57 °F (14 °C). Since lower temperatures
can exist during operating, sensor readings will only be evaluated after the heater
has been running for at least 1 minute.
x
Note
If the heater is defective, Fault F 4 (dr ying/heating temperature sensor, 2R30) is
issued.
If the NTC temperature sensor heating/drying has a short circuit, corresponding to
482 °F, the heater is switched off immediately.
Descriptive Technical Documentation
DTD no. 12-9800 030-5
05.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.