2.5 Insufficient air detection
The temperature sensor heating/drying (2R30) monitors the temperature increase
in the heater bank.
If the air paths are clogged during heating, the temperature in the heater bank
rises rapidly.
This is detected and the fault message insufficient air is displayed.
If the temperature at the temperature sensor heating/drying (2R30) exceeds 356
°F (180 °C), fault code F 66 leaking air is issued.
2.6 Operating hours meter
The time is counted from program start to the end of cool down, without the time
for delay start and anti-crease action.