Operating and installation instructions
Cooker hood
DA 3160
DA 3190
To avoid the risk of accidents
or damage to this appliance
it is essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 07 777 880
en - AU, NZ
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Cooker hood

Operating and installation instructionsCooker hoodDA 3160DA 3190To avoid the risk of accidentsor damage to this applianceit is essential to read these

Page 2 - Contents

Guide to the appliance10

Page 3 - Caring for the environment

a Exhaust socket ø 150 mmb Control panelc Grease filterd Pull-out deflector platee Hob lightingf Charcoal filter(extra accessory available to orderfor

Page 4 - Safety with children

The cooker hood works with. . . air extraction:The air is drawn in, cleaned by thegrease filter and then directed outside.If the on-site ventilation s

Page 5 - Technical safety

The cooker hood is operated by pullingout and pushing in the deflector plate.To switch the fan on^Pull out the deflector plate.The fan will begin to o

Page 6

Automatic switch-off of the IntensivesettingYou can set the Intensive setting so thatit only runs for 10 minutes beforereverting automatically to leve

Page 7

Before any cleaning or maintenancework is carried out, disconnect thecooker hood from the mains supply.Ensure that:– it is switched off at the wall so

Page 8 - Correct use

ControlsThe controls may sufferdiscolouration or damage if soiling isleft on them for too long. Removesoiling straight away.Observe the General notes

Page 9 - Accessories

Cleaning the grease filters by hand^Clean the filters with a soft nylonbrush in a mild solution of hot waterand a small amount of washing-upliquid.Do

Page 10 - Guide to the appliance

Fitting and replacing thecharcoal filterIf the cooker hood is connected forrecirculation, a charcoal filter (optionalaccessory) must be inserted in ad

Page 11

Changing a halogen lamp^Pull out the deflector plate, andremove the grease filter as describedearlier.^Switch off the fan and the lighting.Exercise ca

Page 12 - Description of the functions

Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Warning and Safety instructions . . . .

Page 13 - Operation

DA 3160DA 3190*1) In extraction mode: when measuringfor the height of the wall housing unitand the cut-out, account must be takenof any accessories fi

Page 14

Safety distance between hob andcooker hoodThe minimum safety distancesbetween the top of a cooker or hoband the bottom of the cooker hoodare as follow

Page 15 - Cleaning and care

Installation accessoriesInstallation22

Page 16

a 1 exhaust connection for exhaustducting C 150 mm.b 1 non-return flapfor fitting into the exhaust socket onthe motor unit (only for air extractionmod

Page 17

Installation24

Page 18

Positioning the appliance inthe wall housing unitTo position the appliance correctly,cut the spacer strip to required depthT, and then attach it to th

Page 19

^Screw the brackets onto the right andleft inside walls of the housing unit asshown. The back edge of thebrackets should align with the verticalline d

Page 20 - Appliance dimensions

^When fitting a DA 3190 into a 60 cmhousing unit, unscrew the bracketson the deflector plate whilst it ispulled out.^Lift the appliance up into the ho

Page 21

^Loosen the screws of the fixingbrackets on the top of the appliance.^Push the brackets flush to the wallor the cabinet back wall.^Drill respective ho

Page 22 - Installation

Attaching the lightshield^Attach the lightshield (if using).A DML 300 installation kit, available asan optional accessory, is required forthis.This in

Page 23

Disposal of the packingmaterialThe transport and protective packinghas been selected from materials whichare environmentally friendly fordisposal, and

Page 24

Replacing the grease filter^Remove the protective strip aroundthe edge of the grease filter.Replace the grease filter.^To do this, pull the deflector

Page 25

^Place the exhaust ducting on the fanconnection for the cooker hood.^See "Connection for air extraction" forfurther instructions on fitting

Page 26

Important: To avoid the danger oftoxic fumes, please observe theWarning and Safety instructions.This is especially crucial when usingthe cooker hood a

Page 27

Condensate trap(optional accessory)In addition to insulating the exhaustducting, we recommend that a suitablecondensate trap is also installed tocolle

Page 28

Silencer(optional accessory)To achieve even further reductions innoise levels, a special silencer can befitted in the ducting system...with air extra

Page 29

All electrical work should beundertaken by a suitably qualifiedand competent person in strictaccordance with current nationaland local safety regulati

Page 30

The Miele DSM 400 control module canbe used to combine the cooker hoodwith other components.It enables the following:Connection to a window contactswi

Page 31

Connection to a light switchThe control module can be used toswitch on the cooker hood lighting via alight switch in the house.InstallationThe control

Page 32 - Connection for air extraction

In the event of a fault which you cannotcorrect yourself, or if the appliance isunder warranty, please contact:–your Miele Chartered Agent oror–MieleY

Page 33

Connected load ... max. 395 WFan motor ...max. 295 WHob lighting ...2x50WVoltage ...230VFrequency...

Page 34

This appliance complies with allrelevant local and national safetyrequirements. Inappropriate usecan, however, lead to personal injuryand damage to pr

Page 35 - Electrical connection

Alteration rights reserved / 0510M.-Nr. 07 777 880 / 00

Page 36

Technical safety~Before installation, check the cookerhood for visible signs of damage.Under no circumstances should youuse a damaged appliance. It co

Page 37

~Do not connect the appliance to themains electricity supply by amulti-socket unit or an extension lead.These do not guarantee the requiredsafety of t

Page 38 - After sales service

In order to ensure safe operation, andto prevent gases given off by theheating appliances from being drawnback into the room when the cookerhood and t

Page 39 - Technical data

Correct use~Never use an open flame beneaththe cooker hood. To avoid the dangerof fire, do not flambé or grill over anopen flame.When switched on, the

Page 40 - M.-Nr. 07 777 880 / 00

Correct installation~Refer to the cooker or hobmanufacturer's instructions as towhether a cooker hood may beoperated above the cooker/hob.~The mi