Operating and InstallationInstructionsVentilation SystemDA 249-3To prevent accidentsand machine damage,read these instructionsbeforeinstallation or us
The hood offers two modes ofoperation:Air extractionThe air is drawn in and cleaned by thedecor panel and the grease filter anddirected outside.The ho
Turning on the fan^Press the On/Off button.The fan runs at power level "2".The On/Off indicator lights.Selecting the power level^Use the _ c
Delayed Shut DownIf odors or smoke remain in the kitchenafter cooking has been completed, theDelayed Shut Down feature can beselected to allow the hoo
Filter timersGrease filterA timer monitors the hours of fanoperation. The indicator for the greasefilter will light after 30 hours ofoperation. The gr
Reprogramming the timersThe grease filter timer is preset to 30hours. This time can be lengthened orshortened to 20, 30, 40 or 50 hours.–A time of 20
Reprogramming the charcoal filtertimerThe active charcoal filter can only beused in recirculation mode and can notbe used to exhaust fumes.The charcoa
Before cleaning or servicing thehood, disconnect it from the powersupply by either removing the fuse,unplugging it from the outlet ormanually "tr
Grease filterThe unit of decor panel and reusablemetal grease filter remove solidparticles from the vented kitchen air(grease, dust, etc).The grease f
^Clean the grease filter- by hand: use a scrub brush inwarm water with a mild detergent.- in a dishwasher: place the filter inthe lower basket, making
Active charcoal filtersIn recirculation mode an activecharcoal filter must be used in additionto the grease filter. The charcoal filter isdesigned to
2
Replace the active charcoal filter whenthe charcoal filter indicator lights.Replace the filter at least every 6months or when it no longer absorbodors
Changing the light bulbsBefore changing the light bulbs,disconnect the hood from the powersupply by either removing the fuse,unplugging it, or manuall
In the event of a fault which you can notcorrect yourself please contact theMiele Technical Service DepartmentU [email protected] 1
Installation Instructions
24
Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an
Installation accessories26
a 2 recirculation vents(recirculation mode only)b 2 protective shieldsprevent scratches to the chimneyduring installation.c 1 diverter(recirculation m
The majority of the weight of theinstalled ventilation system will besupported by the lower retainingplate. It must be firmly attached tothe stud fram
All electrical work should beperformed by a qualified electricianin strict accordance with nationaland local safety regulations.Installation, repairs
IMPORTANT SAFETY INSTRUCTIONSGuide to the hoodFunctional descriptionOperationMain power switch . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appliance dimensions30
Cut out area in wall or ceiling forentrance of 6" (150 mm)ductwork or 5" (125 mm)ductwork with a reducing collar.Do not install this exhaust
Installation instructionSee the enclosed installation instructionsheet.Please read the "Important SafetyInstructions" and Installationinstru
,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.The exhaust gases extracted bythe h
– If the exhaust is ducted into aninactive flue, the air must be expelledparallel to the flow direction of theflue.Never connect an exhaust hood toan
M.-Nr. 06 171 760 / 00Alteration rights reserved / 1804This paper was bleached without the use of chlorine.
Read these Operating Instructions carefully before installing orusing the Ventilation System.This appliance is intended forresidential use only. Use t
This equipment is not designed formaritime use or for use in mobileinstallations such as caravans oraircraft. However, under certainconditions it may
, WARNING - TO REDUCETHE RISK OF A RANGE TOPGREASE FIRE:Never leave surface unitsunattended at high settings.Boilovers cause smoking and greasyspillov
Installation, WARNINGTo reduce the risk of fire onlyuse metal ductwork.When installing the hood, follow therecommended minimum safetydistances between
Guide to the hood8
a Chimney extensionb Recirculation ventc Chimneyd Canopye Overhead lightingf Active Charcoal FilterAvailable to purchase, for use in therecirculation