Installation Instructions
DA398-6, DA399-6 en - CA
Installation, repair and maintenance work should be performed by
a Miele authorized service technician in accordance with national
and local safety regulations and the provided installation instructions.
Page view 0
1 2 ... 15

Summary of Contents

Page 1 - Installation Instructions

Installation Instructions DA398-6, DA399-6 en - CA Installation, repair and maintenance work should be performed by a Miele authoriz

Page 2 - Installation

Exhaust duct31Condensate trap In addition to insulating the exhaustduct, we recommend installing acondensate trap to collect andevaporate any con

Page 3

Electrical connection32WARNING: TO REDUCE THE RISKOF FIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS, OBSERVETHE FOLLOWING:All electrical work should beperf

Page 4

Service and warranty33For faults that you cannot resolve onyour own, please contact your Mieledealer or Miele Technical Service.The telephone number f

Page 5

Technical data 34Fan motor 350 WCooktop lighting 2 x 50 WTotal connected load 450 WVoltage, Frequency 120 V AC, 60 HzFuse rating 15 APower cord length

Page 6

9 Independence WayPrinceton, NJ 08540Phone:Fax:www.mieleusa.comU.S.A.Miele, Inc.National HeadquartersPlease have the model and serial numberof your a

Page 7

M.-Nr. 09 968 240 / 02en-USDA 398-6DA 399-6

Page 8

Installation23Before installation Before installing the appliance,read all of the information containedin this chapter and also in the"IMPORTANT

Page 9

Installation24Installation parts

Page 10 - Exhaust duct

Installation25a3 protective installation sheetsfor use when installing the chimney b1 exhaust connectorfor an exhaust duct  6" (150 mm). c1 redu

Page 11 - Electrical connection

Installation26Appliance dimensionsThe drawing is not to scale.aExtraction bRecirculation cAir vent positioned at top for recirculation

Page 12 - Service and warranty

Installation27deMounting area (only d is required for recirculation hoods). Wall and ceilingarea for exhaust duct opening and for wall socket installa

Page 13 - Technical data

Installation28Installation recommendations– We also recommend a distance of atleast 25 ¹/₂" (650 mm) above electriccooktops to provide more works

Page 14 - 33332 Gütersloh

Installation29Plywood backingThe majority of the weight of theinstalled ventilation system will besupported by the lower retainingplate. It must be fi

Page 15 - DA 399-6

Exhaust duct30WARNING: Danger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk o