Miele PW 5065 Service Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
2 Function
2.1 Water path control unit and motor, M24
Driven via 230 V motor. Water path control unit position established via slip
contacts and time measurement.
2.2 Water intake monitoring
Water Control System (WCS):
With water intake monitoring, a closed on-site tap, water pressure that is too low
or a major leak, e.g. due to a missing fluff filter, can be detected.
During water intake the pressure increase is monitored to ensure that a pressure
increase of 8 mm wc occurs within 75 s. If this is not registered, the programme is
cancelled and a Water intake fault is indicated.
Hot water/Alternative water only: With the programmable water intake option
Hot water/Alternative water activated, the fault is registered but the programme
is continued with cold water intake only.
2.3 Water overflow monitoring
If a water level of 220 mm wc is reached, the drain pump/valve is activated until
the level drops to 180 mm wc.
2.4 Alternative water
PW 6055, PW 6065
The alternative water intake is via the main wash compartment.
For retrofitting of alternative water supply valve, see Alternative water valve fitting,
040 4.1.
Descriptive Technical Documentation
040-2 DTD no. 511-6055
This information should not be duplicated or passed on without Miele approval. All rights reserved. 15.06.2005, DE_en