Page view 51
Function test
Check all gas fittings for leaks.
^
Reassemble the appliance.
^
Check the burner flame by operating
the burner.
The flame must not go out on the
lowest setting, or when the control is
turned quickly from a high to a low
setting.
On the highest setting, the flame
must have a distinctive and visible
core.
^ Stick the label supplied with the jets
above the label stating the type of
gas being used.
Conversion to another type of gas
52