Technical Information
CVA4070 / CVA4075 Coffee Systems
6.3.9
Faulty EEPROM/Wrong data
• Install a new control electronic.
.3.10 F42
egistered
• Verify correct source voltage & frequency.
.3.11 F47
power electronic.
• Check the cable between control electronic and power electronic.
• Replace the connecting cable if necessary.
.3.12 F73 – Faulty Brew Unit
When the brew unit is activated, if one of the two microswitches does not
switch within approx.10seconds. F73 is registered.
1 Microswitch position controltop (home position)
2
• Remove any foreign matter.
•
F41
• Control electronic EPX – Remove
6
Main power frequency not r
6
Faulty interface of control electronic and
6
Microswitch position control bottom (compress and drain position)
Figure 6-1: CVA4070 Faulty Brew Unit
Brew unit blocked.
• Disconnect the appliance from the main power supply.
Clean the affected components
129