CVA4070 / CVA4075 Coffee Systems
Defective microswitch or no continuity in connectors.
Check the connecting cables.
Replace the connecting cables as necessary.
Position control microswitch– Check
Replace the microswitch if necessary.
Brew unit drive defective.
Note
W o the home
position, refer to Figure 6-1. Brew unit drive, home position.
hen installing the brew unit, make sure that the pawl is set t
Install a new brew unit drive.
6.3.13
(2R1) does not heat.
Flow-thru heater coffee/hot water – Check
If necessary, Flow-thru heater coffee/hot water – Remove
6.3.14
Flow-thru heater steam does not heat.
Install a new flow-thru heater steam.
m
ration of coffee
and hot water until service is performed, the customer can switch the
off.
F80 Cause
Flow-thru heater coffee/hot water
Install a new flow-thru heater coffee/hot water.
Temperature fuse has tripped.
Replace the temperature fuse.
F81
Flow-thru heater steam – Check
If necessary, Flow-thru heater steam – Remove
Te perature fuse has cut out.
Note
To be able to continue using the appliance for the prepa
steam system off, refer to Steam system – On/