Operating and Installation instructionsRangehoodDA 2050To avoid the risk of accidentsor damage to the appliance,it is essential to read theseinstructi
a Lighting switchb Fan switchc Cooktop lightingd Charcoal filtersSpecial accessory for recirculationmodee Grease filterGuide to the appliance10
To switch the lighting on andoffThe cooktop lighting a can beswitched on and off independently ofthe fan."0" - lighting off"1" - l
Before any cleaning or maintenancework is carried out, disconnect therangehood from the mains supply.Ensure that:– it is switched off at the isolator,
To avoid damaging the filter or thecooktop below, make sure you holdthe filter securely at all times whenhandling it.Cleaning the grease filter by han
Fitting and replacing thecharcoal filtersIf the rangehood is connected forrecirculation, two charcoal filters mustbe inserted in addition to the greas
Changing a halogen lampBefore any cleaning or maintenancework is carried out, disconnect therangehood from the mains supply.Ensure that:– it is switch
*Cut-out dimensionsA depth T of at least 25 mm must beprovided at the back of the building-inniche.Safety distances between cooktopand rangehood (S)Th
–When deciding on the safetydistance between the cooktop andrangehood, please note that adistance of 650 mm above electriccooktops may be preferable t
Fitting the non-return flap(Air extraction mode only)^ If a non-return flap is not present inthe venting system, the non-returnflap supplied must be f
Preparation for extraction^When using C 150 mm ducting,secure the exhaust connectionsupplied to exhaust ducting withhose clips.^Place the exhaust duct
Caring for the environment...3Warning and Safety instructions ...4Modes of op
^Dismantle the non-return flap.^Take the on-site conditions intoaccount when fitting the conversionkit.When fitting the exhaust grille, makesure that
Important: To avoid the danger oftoxic fumes, please observe theWarning and Safety instructions.This is especially crucial when usingthe rangehood at
Condensate trap(optional accessory)For installations in areas where theexhaust ducting is exposed to coldtemperatures, we recommendinsulating the exha
Silencer(DASD 150, optional accessory)To achieve even further reductions innoise levels, a special silencer can befitted in the ducting system...with
All electrical work should beundertaken by a suitably qualifiedand competent person in strictaccordance with current nationaland local safety regulati
In the event of a fault which you cannotcorrect yourself, please contact:–MieleYou will find the telephone numberand address of Miele on the backcover
Total rated load ...185W- Fan motor ...85W- Cooktop lighting ...2x50WVoltage ... AC230VFrequency ...
27
Alteration rights reserved / 3013M.-Nr. 09 723 310 / 00
Disposal of the packingmaterialThe transport and protective packinghas been selected from materials whichare environmentally friendly for disposaland
This appliance complies with allrelevant local and national safetyrequirements. Inappropriate usecan, however, lead to personalinjury and damage to pr
Technical safety~Before installation, check therangehood for visible signs of damage.Under no circumstances should youuse a damaged appliance. A damag
~Do not connect the appliance to themains electricity supply by amulti-socket unit or an extension lead.These do not guarantee the requiredsafety of t
In order to ensure safe operation, andto prevent gases given off by theheating appliances from being drawnback into the room when the rangehoodand the
~Do not use the rangehood withoutthe filters in place. This way you willavoid the risk of grease and dirt gettinginto the appliance and hindering itss
The rangehood works with. . . air extraction:The air is drawn in, cleaned by thegrease filter and then directed outside.If the on-site ventilation sys