~Safety regulations prohibit the fittingof a cooker hood over solid fuel stoves.~All ducting, pipework and fittingsmust be of non-flammable material.T
The cooker hood works with. . . air extraction:The air is drawn in and cleaned by thegrease filters and directed outside.If the on-site ventilation sy
Guide to the appliance12
a Extension pieceb Towerc Canopyd Control panele Grease filtersf Recirculation grille(only for recirculation mode)g Hob lightingh Charcoal filter(spec
Con|ctivityThis cooker hood is communicationenabled.Communication module XKM 2000 DAa, available as an optional extra,enables the operation of the coo
Switching on the fan^Press the On/Off touch control.The fan runs at power level "II".The indicator lamp will come on.If the cooker hood has
The indicator lamps for fan power levels"I" and "IV" will flash if the automaticswitch-off of the Intensive setting is notactivate
Switching the lighting onThe hob lighting can be switched onand off independently of the fan.^Briefly press the lighting touchcontrol to switch on the
Filter operating hours counterThe number of hours the appliance hasbeen in operation is stored in memory.The indicator lamp for the grease filtertouch
Filter operating hours counterYou can set the operating hourscounter to suit the type of cooking youdo.–Select a short time if you roast or frya lot.–
Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Warning and Safety instructions . . . .
Setting and altering the charcoalfilter operating hours counter(with recirculation mode)The charcoal filter is needed forrecirculation mode.The cooker
Before carrying out any cleaning ormaintenance work, disconnect thecooker hood from the mains supply.Ensure that:– it is switched off at the wall sock
ControlsThe controls may sufferdiscolouration or damage if soiling isleft on them for too long. Removesoiling straight away.Observe the General notes
Cleaning the grease filters by hand^Clean the filters with a soft nylonbrush in a mild solution of hot waterand a little washing-up liquid.Do not use:
Fitting and replacing thecharcoal filterIf the cooker hood is connected forrecirculation, a charcoal filter must beinserted in addition to the grease
Changing a halogen lampBefore any cleaning or maintenancework, disconnect the cooker hoodfrom the mains supply. Ensure that– it is switched off at the
DA 406DA 407DA 4091) Extraction2) Recirculation3) Ventilation grille position forrecirculation4) and 5):(5 is not required for recirculation modecooke
Safety distance between hob andcooker hood (S)When planning the installation heightof your cooker hood, the minimumsafety distance between the top of
Assembly partsInstallation28
a 3 protective sheetsfor use when fitting the tower.b 2 hose clipsfor securing the exhaust ducting.c 1 reducing collarfor exhaust ducting C 125 mm.d 1
Operation with Control module DSM 400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Connection to a window contact switch ...
Before installation, it is important toread the information given on thefollowing pages as well as the"Appliance dimensions" and the"Wa
All electrical work should beundertaken by a suitably qualifiedand competent person in strictaccordance with current nationaland local safety regulati
The Miele DSM 400 Control module canbe used to combine the cooker hoodwith other components.It enables the following:Connection to a window contactswi
Connection to a light switchThe control module can be used toswitch on the cooker hood lighting andalso to dim it, depending on model, viaa light swit
Important: To avoid the danger oftoxic fumes please observe theWarning and Safety instructions.This is especially crucial when usingthe cooker hood at
Important:If the exhaust ducting is to run throughrooms, ceiling space etc. where theremay be great variations in temperaturebetween the different are
In the event of a fault which you cannotcorrect yourself, or if the appliance isunder guarantee, please contact:–Your Miele Dealer / Chartered Agentor
Total connected load * ...300WFan motor* ...200WHob lighting ...2x50WVoltage ... AC230VFrequency...
38
39
Disposal of the packingmaterialThe transport and protective packinghas been selected from materials whichare environmentally friendly fordisposal, and
Alteration rights reserved / 4209M.-Nr. 07 285 740 / 02
This appliance complies with allrelevant local and national safetyrequirements. Inappropriate usecan, however, lead to personal injuryand damage to pr
Technical safety~Before installation, check the cookerhood for visible signs of damage.Under no circumstances should youuse a damaged appliance. A dam
~Do not connect the appliance to themains electricity supply by amulti-socket unit or an extension lead.These do not guarantee the requiredsafety of t
In order to ensure safe operation, andto prevent gases given off by theheating appliances from being drawnback into the room when the cookerhood and t
Correct use~Never use an open flame beneaththe cooker hood. To avoid the dangerof fire, do not flambé or grill over anopen flame.When switched on, the