Operating and InstallationInstructionsVentilation SystemDA 5960 WDA 5980 WDA 5990 WTo prevent accidentsand appliance damage,read these instructionsbef
Turning on the fan^Press the On/Off button.Selecting the power level^Use the "–/+" controls to select thedesired power level.+ = increases t
If the power level indicators "1" and "4"flash, the automatic switch back is notactivated.^To activate the automatic switch backpr
Turning off the fan^Press the On/Off button to turn thefan off.The indicator goes out.Automatic Safety Shut OffThe fan will turn off automatically10 h
,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before cleaning or servicing thehood, disconnect it from
Grease filterThe reusable metal grease filterremoves solid particles from the ventedkitchen air (grease, dust, etc).The grease filter should be cleane
Cleaning the grease filter^By hand: use a scrub brush with asolution of warm water and milddetergent.Do not use pure detergent,aggressive all purpose
Active charcoal filterIn recirculation mode an activecharcoal filter must be used in additionto the grease filter. The charcoal filter isdesigned to a
Changing the light bulbs,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before changing the light bulbs,d
RepairsIn the event of a fault which you cannoteasily fix yourself, please contact theMiele Technical Service Department.^When contacting the Technica
Installation InstructionsRead these instructions and the "Important Safety Instructions" before installingthis ventilation system.The instal
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Functional description . . . . . . . . . . . . . . . .
Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an
Appliance dimensions22
1) Air extraction mode2) Recirculation mode3) Recirculation vent installed upwards4) and 5) Installation areaWall/ceiling area respectively for ventho
Distance between cooktop and hood (S)Do not install this exhaust hood over cooktops burning solid fuel.Provided a larger distance is not given by the
The installation procedure differsdepending on the model and ventingmethod.Before beginning the installation:^Read all instructions.^Determine height
Installation accessories26dai2701us
a 3 protective shieldsto prevent scratches to the chimneyduring installation.b 1 vent collarfor use with 6" (150 mm) exhaustductingc 1 reducing c
The majority of the weight of theinstalled ventilation system will besupported by the lower retainingplate. It must be firmly attached tothe stud fram
Protective filmThe casing is covered with a protectivefilm to prevent scratching duringtransport.^Peel off the film before installing thecasing parts.
READ AND SAVE THESEINSTRUCTIONSKeep these instructions in a safeplace and pass them on to any futureuser.Read these instructions carefullybefore insta
,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk of fire and topr
– If the exhaust is ducted into aninactive flue, the air must be expelledparallel to the flow direction of theflue.Never connect an exhaust hood toan
,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:All electrical work should beperformed by a qualified ele
Maximum load ...400WFan...350WOverhead lighting ...1x50WVoltage ...120VFrequency ...
Alteration rights reserved / 2411INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOSTCURRENT PRODUCT SPECIFICATIONS, TECHN
~d) Before connecting the applianceto the power supply make sure that thevoltage and frequency listed on thedata plate correspond with thehousehold el
,WARNINGTO REDUCE THE RISK OFINJURY TO PERSONS IN THEEVENT OF A COOKTOPGREASE FIRE, OBSERVE THEFOLLOWING*:~a) SMOTHER FLAMES with a closefitting lid,
Installation,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:~a) Installation work and electricalwiring mu
The ventilation hood offers two modes of operation:Air extractionThe air is drawn in and cleaned by thegrease filter and directed outside.The hood com
Guide to the Ventilation System8
a Chimney extensionb Chimneyc Control paneld Overhead lightinge Recirculation vent(only in recirculation mode)f Canopyg Active Charcoal Filterh Grease
Comments to this Manuals