Miele KM 93-2 User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
Conversion to alternative types of gas
When converting to alternative
types of gas, the main and small
jets of all burners must be changed.
Select the new jets following the table
below. The gas cooktop is supplied
equipped for natural gas; the appropri-
ate gas jet kit for propane gas, LPG, is
also supplied with the appliance.
Reference table - jet sizes
Main jet
diameter
Small jet
diameter
Natural gas
Normal burner
Fast burner
1.22 mm
0.048"
1.55 mm
0.061"
0.48 mm
0.019"
0.57 mm
0.023"
LP gas
Normal burner
Fast burner
0.72 mm
0.028"
0.91 mm
0.036"
0.32 mm
0.013"
0.40 mm
0.016"
Conversion to LP Gas
Turn off the main gas supply (if the
appliance has already been in-
stalled) and turn off the main electri-
cal supply.
Remove the pan supports and the
burner caps.
With a suitable tool, loosen and
remove the brass ring in each burner
head.
Remove the burner heads.
Pull the control knobs for the gas bur-
ners up and off.
Carefully raise the cooktop slightly at
the rear, pull forward and lift the con-
trol panel up. To avoid having to
remove the ground wire, stand the
control panel up against the wall be-
hind the cooktop.
Conversion to alternative types of gas
24
Page view 23
1 ... 23 24 25 26 27 28

Comments to this Manuals

No comments