Page view 65
Problem Possible cause Remedy
F and a number appear
in the display.
F20 The water container has
not been pushed right
into the appliance so that
it connects.
Remove the water
container, push it in
correctly so that it
connects, then switch the
appliance off and back
on again.
The coupling seal on the
water container is stiff.
The water container
cannot be fully pushed
into place.
Lightly lubricate the
coupling seal on the
water container with
silicone grease, as
described in "Cleaning
and care / Water
container / Coupling
seal".
F44 Communication fault Switch the appliance off,
then switch it on again a
few minutes later. If F 44
is still showing in the
display, call the Service
Department.
F55 The maximum operating
duration on the Fan plus
function has been
exceeded, and safety
switch-off has been
triggered.
The appliance will be
ready for use again after
it has been switched off
and then back on again.
F..
Any other fault
messages
Technical fault. Switch the appliance off
and call the Service
Department.