Page view 40
When installing two or more appliances next to each other a spacer bar b must
be used between each one.
See "Fixing the spring clamps and spacer bars".
Worktop cut-out
- two appliances
Worktop cut-out
- three appliances
To calculate the cut-out width (D) required:
Add up the widths of each appliance (e.g. 288 mm, 380 mm) and subtract 16 mm
from this figure
Number of
appliances
Appliance width in mm Worktop cut-out in mm
1 288 288 - 16 = 272
2 288, 288 288 + 288 - 16 = 560
2 288, 380 288 + 380 - 16 = 652
3 288, 288, 288 288 + 288 + 288 - 16 = 848
3 288, 288, 380 288 + 288 + 380 - 16 = 940
Installation of several appliances