3.4 F 0, no fault
Cause
No fault saved in the power-programme module (ELP) fault memory.
Remedy
A None required.
3.5 Fault code F 1, water/heating NTC sensor short-circuited
Symptom
In normal operation mode this fault is not indicated via the display.
The heating is switched off after approx. 10 s.
The programme continues without heating.
Hot water operation: The programme continues with cold water.
Cause
NTC temperature sensor (R30) or its connections short-circuited.
NTC temperature sensor (R30) check
A Check the NTC temperature sensor in the service mode.
A PW 6055 and PW 6065: Service mode, see Service mode summary, 080 4.5.
A PW 5065: Service mode, see Service mode summary, 080 4.6.
A Check the NTC temperature sensor and its connections for an open or short
circuit, and correct insulation.
A Check the NTC temperature sensor resistance, see 030 Table 1.
Descriptive Technical Documentation
080-8 DTD no. 511-6055
This information should not be duplicated or passed on without Miele approval. All rights reserved. 15.06.2005, DE_en