3.21 Fault code F56, no spin
PW 6055, PW 6065
Symptom
Final spin speed < 400 rpm even though the desired speed is at least 450 rpm.
Fault registered via tachogenerator.
Cause
Final spin speed < 400 rpm even though the desired speed is at least 450 rpm.
Remedy
A Check dispensed quantities, see Fault code F16, excess foam, 080 3.10.
A Check the drive, see Drive failure, 070 3.1.
3.22 Fault code F63, water path control unit
Symptom
In normal operation mode the display shows Technical fault.
The solenoid valve is closed and the programme interrupted. The drain pump is
activated for 120 s.
Cause
Water path control system faulty.
The power-programme module (ELP) cannot register a valid position of the water
path control unit within approx. 80 s of it being switched on.
x
Note
Water intake monitoring is not active if a valid position of the water path control
unit cannot be registered.
Check the water path control system
A Check the water path control system circuit for an open or short circuit, and
correct insulation.
Descriptive Technical Documentation
DTD no. 511-6055 080-19
15.06.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.