Miele PW 5065 Service Manual Page 73

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 72
Programmable function Option
Control type, see 080 2.12 Control
programmable function
D As on domestic machines
CH As on domestic machines
GB Launderette
D Launderette
Drum lighting, see 080 2.13 Drum lighting
programmable function
Passive: If a washing machine is without drum lighting, the drum lighting
function must be deactivated.
Active
Standard setting Reset all programmable functions to standard settings
Table 1: Programming mode summary
Save and quit
x
Note
Confirmed programmable options are saved.
A Reconnect the suds temperature sensor (R30) plug to the power-programme
module (ELP).
4.2 Programming mode summary
PW 5065
Initial requirements
A Finish or cancel any programme in operation, including the demonstration
mode.
A Open the door.
A Disconnect the suds temperature sensor (R30) plug from the power-
programme module (ELP).
x
Note
When the suds temperature sensor (R30) plug is disconnected, the door cannot
be opened via the door switch (S4).
A During initial commissioning only: Select the desired language.
Descriptive Technical Documentation
DTD no. 511-6055 080-25
15.06.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.