Miele CVA 2660 Operations Instructions Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
If the water is harder than 7.0 mmol/l or 700 mg/l (40 °d),
limescale will build up more rapidy than with soft water.
Descaling will need to be carried out more regularly than
stated to prevent limescale damage to the appliance.
Use programming option "Water hardness" to programme in
the water hardness.
There are four programmable levels:
Level
(Appliance)
Hardness
(local water)
°d mmol/l Water
through-flow in
litres
Hardness 1 1 (soft) 0 - 3 0 - 1,3 approx. 120
Hardness 2 1 (soft) 4 - 7 1,3 - 2,5 approx. 90
Hardness 3 2 (medium) 7 - 14 2,5 - 3,8 approx. 60
Hardness 4 3 (hard)
4 (very hard)
14 - 21
above 21
above 3,8 approx. 40
SETTINGSF
K 12345L
o
n G k
C
^ Turn the left control dial until you reach the "Settings" menu
option.
PROGRAMMING
F
Y
K n
I
IJZ
^
Turn the right control dial until the "Programming" symbol is
highlighted and then press the control dial.
WATER HARDNESS
n IA M
T
U N
A
^
Turn the right control dial to the "Water hardness" menu op
-
tion and press the control dial to call up the settings.
Settings: Customising your appliance
25
Page view 24