. . . the lighting suddenly switches itself off
The lighting will switch off automatically after 10 minutes of
inactivity.
. . . the display is not legible
If the appliance is set too far back in its niche the display can
be hard to see.
^
Try and improve this by adjusting the display contrast or
brightness.
...you cannot open or close the door
The steam valve is not in the correct upward faciong position.
^ Push the valve right down to start with, and then pull it up-
wards as far as it will go.
. . . Coffee is not dispensed, even though the coffee cap-
sules are in the capsule magazine there is sufficient water
in the water container.
^ Remove the water container and replace it.
. . . Coffee is not dispensed, even though the capsule
magazine is full and there is sufficient water in the water
container.
A coffee capsule has jammed in the capsule magazine.
^
Open the appliance door.
^
Pull the magazine runners out, lift the capsule magazine
upwards and release the coffee capsules so that they can
move without hindrance.
^
Replace the capsule magazine on its runners, and push
the runners as far as they will go into the appliance.
^
Close the door.