. . . there is water in the waste unit
This is not a fault. The water is left over from the brewing and
cleaning process.
. . . there is residual "coffee water" in the waste unit
The capsule plate is not correctly pushed in.
^
Remove the capsule plate and replace it.
. . . the descaling process was started by mistake
The descaling programme cannot be cancelled after the right
hand control dial has been pressed. The programme has to
be completed through to the end. This is a safety measure, to
ensure that the machine is fully descaled and to prevent the
descaling programme being shortened. This is important to
protect the appliance and ensure it functions correctly.
. . . the heating-up time is getting longer, the amount of
water coming through is incorrect and the machine is not
performing properly
^ The machine needs descaling.
. . . after selecting a user profile a different chamber and
coffee size is selected, and not chamber 1 and Espresso
The appliance recognises which drink was last selected by
this user.
. . . the error message F 10 appears
Water has not been taken in. The water container is not cor
-
rectly in place.
^
Remove the water container and push it back into position
again, making sure it engages correctly.
^
If this fault message occurs again, please call the Miele
Service department, quoting the fault code.