Operating and installation instructionsCooker hoodTo avoid the risk of accidents or damage to this appliance,it is essential to read these instruction
Guide to the appliance / Operation10
a Recirculation grille(only for recirculation mode)b Exhaust connectionc Adjustable bracketd Open-out vapour canopyto which a furniture door is fitted
A range of Miele branded cleaning andconditioning products is available toorder from Miele (see back page fordetails) or via the internet atwww.miele-
Grease filtersThe re-usable metal grease filters in theappliance remove solid particles(grease, dust, etc.) from the kitchenvapours, preventing soilin
Charcoal filtersIf the cooker hood is being used onrecirculation mode, two DKF 14-1charcoal filters must be fitted behindthe grease filters.^ Open the
Changing a halogen lamp,Before any cleaning ormaintenance work, disconnect thecooker hood from the mains supply.,Exercise caution when changinghalogen
In the event of a fault which you cannotcorrect yourself, or if the appliance isunder guarantee, please contact:– your Miele Dealeror– the Miele Servi
* Furniture panel dimensionsConnection for air extractionC 150 mm,or C 120 mm with reducing collar.Safety distance between hob andcooker hood (S)The f
Before installation, it is important toread the information given on thefollowing pages as well as theWarning and Safety instructions atthe beginning
Depth adjustment^ The depth of the unit "T" can beadjusted from 275 to 360 mm bymeans of the adjustable brackets.^ Slightly loosen the screw
Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Warning and Safety instructions . . . .
^ The recirculation grille must beremoved when the hood is used inextraction mode.^ Hang the cooker hood in positionusing the adjustable brackets.^ Po
Height adjustment^ Using the screws at the back of theadjustable brackets, align the cookerhood height with that of neighbouringunits. Turn the screw–
With air extraction:If the on-site ventilation system doesnot have a non-return flap, one of thetwo non-return flaps supplied (forC 150 mm or C 120 mm
All electrical work should beundertaken by a suitably qualifiedand competent person in strictaccordance with current nationaland local safety regulati
Important: To avoid the danger oftoxic fumes, please observe theWarning and Safety instructions.This is especially crucial when usingthe cooker hood a
Total connected load...290WFan motor ...250WHob lighting ...2x20WVoltage ... AC230VFrequency...
Technical data2Data sheet for domestic cooker hoodsIn acc. with delegated regulation (EU) No. 65/2014 and regulation (EU) No.66/2014MIELEModel name /
27United KingdomMiele Co. Ltd.Fairacres, Marcham RoadAbingdon, Oxon, OX14 1TWCustomer Contact Centre Tel: 0330 160 6600E-mail: [email protected]
M.-Nr. 10 074 590 / 03en-GBDA 186
Disposal of the packing materialThe packaging is designed to protectthe appliance from damage duringtransportation. The packaging materialsused are se
This appliance complies with allrelevant local and national safetyrequirements. Inappropriate usecan, however, lead to personalinjury and damage to pr
Technical safety~Before installation, check the cookerhood for visible signs of damage.Under no circumstances should youuse a damaged appliance. A dam
~Do not connect the appliance to themains electricity supply by amulti-socket unit or an extension lead.These do not guarantee the requiredsafety of t
In order to ensure safe operation, andto prevent gases given off by theheating appliances from being drawnback into the room when the cookerhood and t
~Do not use the cooker hood withoutthe filters in place. This way you willavoid the risk of grease and dirt gettinginto the appliance and hindering it
The cooker hood works with. . . air extraction:The air is drawn in and cleaned by thegrease filters and directed outside.If the on-site ventilation sy