Operating and installation instructionsCooker hoodDA 3560DA 3590DA 3560 EXTDA 3590 EXTTo avoid the risk of accidentsor damage to this appliance,it is
Guide to the appliance10
a Pull-out deflector plateb Controlsc Grease filtersd Hob lightinge Exhaust socket C 150 mmThe exhaust socket can also be fitted atthe back.f Slots fo
The cooker hood works with. . . air extraction:The air is drawn in, cleaned by thegrease filters and directed outside.If the on-site ventilation syste
Con|ctivityThis cooker hood is communicationenabled.Communication module XKM 2000 DAa, available as an optional extra,enables the operation of the coo
To switch the fan on^Pull the deflector plate downwardsslightly and then towards you.The fan will come on at power level 2.The On/Off symbol K and Fan
Run-on option 5 ¢15It is advisable to run the fan for a fewminutes after cooking has finished toneutralise any lingering odours in theair, whether you
Safety switch-offShould the cooker hood be left on, thefan will switch off automatically after 10hours. The lighting will remain on.^Pressing the On/O
Activating and altering the charcoalfilter operating hours counter (with recirculation mode)The charcoal filters must be fitted forthe cooker hood to
,Before any cleaning ormaintenance work is carried out,disconnect the cooker hood from themains supply.,Exercise caution when changinghalogen lamps. T
ControlsThe controls may sufferdiscolouration or damage if soiling isleft on them for too long. Removesoiling straight away.Please observe the General
Caring for the environment...3Warning and Safety instructions ...4Guide to th
Cleaning the grease filters by hand^Clean the filters with a soft nylonbrush in a mild solution of hot waterand a little washing-up liquid.Do not use
Fitting and replacing thecharcoal filtersIf the cooker hood is connected forrecirculation, two active charcoal filters(optional accessory) must be ins
Changing a halogen lamp^Before any cleaning or maintenancework, disconnect the cooker hoodfrom the mains supply.,Exercise caution when changinghalogen
In the event of a fault which you cannotcorrect yourself, or if the appliance isunder guarantee, please contact:–Your Miele Dealer / Chartered Agentor
Appliance dimensions24
1) Air extraction and recirculation modewith conversion kit DUU 150 if the air isto be directed upwards out of the wallunit.2) Trim the wall unit carc
Installation accessoriesInstallation26
a 1 exhaust socketfor exhaust ducting C 150 mm.b 1 reducing collarfor exhaust ducting C125 mm.c 1 non-return valvefor fitting into the exhaust socket
,Before installation, it is importantto read the information given on thefollowing pages as well as theWarning and Safety instructions atthe beginning
Installation29
Disposal of the packing materialThe transport and protective packinghas been selected from materials whichare environmentally friendly fordisposal, an
^Pull the grease filters out of the slotsin the front of the cooker hoodhousing.The spacer strip needs to be attachedto the back of the cooker hood ho
^Screw the brackets onto the right andleft inside walls of the housing unit sothat they are flush with the bottomedge of the wall unit.The brackets ar
^ Fit the cooker hood into the wall unitfrom below, guiding it over the safetynotch, as shown. Push it back untilthe spacer strip is flush with the wa
When fitting the DA 3590 in a 900 mmwide housing unit, the retainingbrackets supplied are used to align thecooker hood and provide additionalsupport.T
Adjusting the deflector plate(DA 3560, DA 3590)When retracted, the deflector plate isheld in place by magnets.The retaining force of the magnets canbe
^Secure the spacer strip to the bottomof the wall unit as well.^Insert the cover for the charcoal filterslots as shown and close it. It is heldin plac
^ Attach the vent ducting to theexhaust socket, using e.g. a flexiblehose and clips (available as anoptional accessory).When using C 125 mm ducting, f
^Fit the conversion kit as described inthe installation instructions suppliedwith the kit.^Make sure that the slats in theexhaust grille point towards
Important: To avoid the danger oftoxic fumes, please observe theWarning and Safety instructions.This is especially crucial when usingthe cooker hood a
–If the exhaust air is to be ducted intothe open air, the installation of atelescopic wall vent or roof vent(available as an optional accessory)is rec
This appliance complies with allrelevant local and national safetyrequirements. Inappropriate usecan, however, lead to personal injuryand damage to pr
Silencer(optional accessory)To achieve even further reductions innoise levels, a special silencer can befitted in the ducting system...with air extra
All electrical work should beundertaken by a suitably qualifiedand competent person in strictaccordance with current nationaland local safety regulati
The Miele DSM 400 control module(optional accessory) can be used tocombine the cooker hood with othercomponents.It enables the following:Potential fre
Connected load*DA 3560...170WDA 3590...190WFan motor* ...130WHob lightingDA 3560...2x20WDA 35
Alteration rights reserved / 4212M.-Nr. 09 466 100 / 03
Technical safety~Before installation, check the cookerhood for visible signs of damage.Under no circumstances should youuse a damaged appliance. It co
~Do not connect the appliance to themains electricity supply by amulti-socket unit or an extension lead.These do not guarantee the requiredsafety of t
In order to ensure safe operation, andto prevent gases given off by theheating appliances from being drawnback into the room when the cookerhood and t
Correct use~Never use an open flame beneaththe cooker hood. To avoid the dangerof fire, do not flambé or grill over anopen flame.When switched on, the
~All ducting, pipework and fittingsmust be of non-flammable material.These can be obtained from the MieleSpare Parts department or frombuilders'