1) Cut-out for feeding through the
exhaust ducting and the mains cable
Floating bracket C 200 mm
The floating bracket means that the
hood can also be installed where the
exhaust cut-out in the ceiling is not
centrally positioned over the hob. There
is a max. margin of 40 mm in any
direction.
Safety distance between hob and
cooker hood
The minimum safety distances
between the top of a cooker or hob
and the bottom of the cooker hood
are as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
550 mm above electric hobs and
cookers,
650 mm above an open grill or
deep fat fryer,
650 mm above gas hobs and
cookers.
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
See "Warning and Safety" instructions
for further information.
Appliance dimensions
22