Note that since the compensator and DPWM are digital, their transfer functions are known exactly and can be
divided out of the measured open-loop gain. In this way the UCD9246 can accurately measure the power
stage/load plant transfer function in situ (in place), on the factory floor or in an end equipment application and
send the measurement data back to a host through the PMBus interface without the need for external test
equipment. Details of the Auto-ID™ PMBus measurement commands can be found in the UCD92xx PMBus
Command Reference.
Data Logging
The UCD9246 maintains a data log in non-volatile memory. This log tracks the peak internal and external
temperature sensor measurements, peak current measurements and fault history. The LOGGED_PEAKS and
LOGGED_FAULTS PMBus commands and data format for the Data Logging can be found in the UCD92xx
PMBus Command Reference (SLUU337).
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 29