Changing the light bulb
,
To reduce the risk of electric
shock, disconnect the dryer from the
power supply by shutting off the
power main, tripping the circuit
breaker or unplugging the power
cord before performing
maintenance.
^
Open the door.
The bulb cover is located along the
upper rim of the drum opening.
^
Slide a screwdriver with a wide head
underneath the side edge of the bulb
cover and twist (see illustration).
^
Flip down the bulb cover.
^
Replace the light bulb with a
temperature proof bulb, available
from Miele.
The light bulb must not exceed the
maximum wattage listed on the data
plate.
^
Flip up the light bulb cover and press
it firmly until it clicks into place.
,
Make sure the bulb cover is
securely closed to prevent a short
circuit or penetrating moisture.
^ Restore power.