Miele G 1772 Operations Instructions Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
Climate range
The appliance is designed for use
within a certain climate range (ambient
temperatures) and should not be used
outside this range.
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the temperature
inside the appliance to rise with the risk
of food deteriorating and going off.
The climate range of the appliance is
stated on the data plate inside the
appliance.
Climate range Ambient room
temperature
SN
N
ST
T
+10°C to +32°C
+16°C to +32°C
+16°C to +38°C
+16°C to +43°C
A freezer from the SN climate range
can operate without any difficulties in
rooms with a cooler ambient
temperature (down to +5 °C).
Ventilation
The ventilation gaps given must be
adhered to, otherwise the
compressor will be activated more
frequently and for longer periods.
This will result in increased energy
consumption and a higher operating
temperature for the compressor.
This may, in turn, cause the
compressor to be damaged.
Air at the back of the appliance gets
warm. The appliance housing unit must
therefore be constructed to allow
sufficient space for ventilation (see
"Building-in dimensions").
Air intake a occurs via the plinth at
the bottom of the appliance and the
air escapes at the top b at the rear
of the housing unit.
A ventilation gap of at least 40 mm
depth must be allowed for behind the
appliance for air to circulate.
Installation advice
58
Page view 57
1 ... 57 58 59 ... 84

Comments to this Manuals

No comments