The water needs to be softened to
avoid calcium deposits building up on
instruments and utensils and in the
machine itself.
To ensure a steady supply of soft water
the water softener unit must always be:
1. correctly set (programmed) and
2. the salt reservoir must be filled.
(If the water hardness level is below
0.7 mmol/l (4 °d - German scale) the
reservoir does not need to be filled
with reactivation salt.)
The machine is set at the factory for
a water hardness level of 3.4 mmol/l
(19 °d).
If the water supply is harder or softer
than this (including below 0.7 mmol/l
or 4 °d) the factory setting will need
to be changed following the
instructions in "Setting the water
softener". See chart on the next
page for settings.
Your local water authority will advise
you on the water hardness in your area.
For fluctuating levels (e.g. 1.4 -
3.1 mmol/l or8-17°d)setthewater
softener to the highest setting (in this
example to 3.1 mmol/l or 17 °d).
Important
The built-in water softener has settings
from 0.2 - 10.8 mmol/l or 1 °d - 60 °d.
Setting the water softener
^
Switch off the machine.
^
Turn the programme selector to the
STOP position f.
^
Press 4 and 6 at the same time,
hold them in and, whilst doing so,
switch the machine on with the I-0
button.
The current programme status "P..."
will show in the display.
The indicator light p / 6 will come
on.
^
Press 3 once, E01 for programming
level 1 will appear in the display.
^ Turn the programme selector one
switch position clockwise (1 o’clock
position).
The number 19 appears in the
display (the factory water hardness
setting in °d), (equivalent to
3.4 mmol/l).
^ Press 4 as many times as is
necessary, or hold it in until the
required value (hardness level in °d)
appears in the display.
Once the number 60 has been
reached, the counter will begin again
at 0.
^
Press the 6 button. SP appears.
^
Press 6 again. The setting will now
be stored in memory. The display will
go out.
^
The machine is now ready for use.
Water softener
16