All electrical work must be
carried out by a suitably qualified
and competent person in
accordance with local and national
safety regulations (BS 7671 in the
UK).
–
Connection should be made via a
suitable isolator, with an on-off switch
which should be easily accessible for
servicing work.
–
For extra safety it is advisable to
install a suitable residual current
device. Contact a qualified electrician
for advice.
WARNING
THIS APPLIANCE MUST BE
EARTHED
– Equipotential bonding should be
carried out.
Bonding connection
There is a screw connection point
marked with the earth symbol (
8)at
the back of the machine, to which the
earth lead must be connected.
For technical data see data plate or
wiring diagram supplied.
The machine must only be operated
with the voltage, frequency and fusing
shown on the data plate.
This machine can be converted in
accordance with the conversion
diagram and wiring diagram supplied.
The conversion diagram and data
plate with test certification (VDE, DVGW
etc.) is located on the rear of the
machine, and on the plinth (behind the
service panel).
– The wiring diagram is secured to
the inner side of the service panel.
50
Electrical connection