Miele PT 7135 C Service Manual

Browse online or download Service Manual for Electric laundry dryers Miele PT 7135 C. Miele PT 7135 C Technical data User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Descriptive Technical
Documentation
- Model-dependent -
DTD no. 521-7135
Model(s): PT 7135 C, PT 7136, PT 5135 C,
PT 5136
14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Page view 0
1 2 3 4 5 6 ... 87 88

Summary of Contents

Page 1 - DTD no. 521-7135

Descriptive TechnicalDocumentation- Model-dependent -DTD no. 521-7135Model(s): PT 7135 C, PT 7136, PT 5135 C,PT 513614.10.2005, DE_en This information

Page 2

4 Touch current measurementxNoteOn machines with an earth connection, touch current leakage measurementsshould be carried out on all accessible conduc

Page 3 - Contents

B Modification HistoryWhen? Who? What?11.05.2005 Olaf Meyer zu Drewer Initial compilationDescriptive Technical DocumentationDTD no. 521-7135 B-114.10.

Page 4

Descriptive Technical DocumentationB-2 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights reser

Page 5 - 090 Electrical components

C Technical DataSemi-commercialmachinesPT 7135 C PT 7136 PT 5135 C PT 5136Condenser dryer Vented dryer Condenser dryer Vented dryerCasing Generation 2

Page 6 - 4 DTD no. 521-7135

Descriptive Technical DocumentationC-2 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights reser

Page 7 - 1 General information

D Layout of Electrical ComponentsPT 7135 CxLayout 11 (Z1) Interference suppression capacitor2 X3/1 Mains terminal strip3 (1K1/1, 2K1/1, 3K1/1) Heating

Page 8 - A-2 DTD no. 521-7135

11 (2R30) Drying air NTC temperature sensor - In heater bankbehind perforated rear drum panel12 (R1, R2, R3) Heater bank13 (A2) Door lock14 (C5) Capac

Page 9

PT 5135 CxLayout 21 (Z1) Interference suppression capacitor2 X3/1 Mains terminal strip3 (1K1/1, 2K1/1, 3K1/1) Heating relay4 (X1/1) Payment system soc

Page 10 - 4 Touch current measurement

12 (R1, R2, R3) Heater bank13 (A2) Door lock14 (C5) Capacitor - Drum drive15 (M5) Motor - Air flow and drum drive16 (1R30) Drying air NTC temperature

Page 11 - B Modification History

PT 7136xLayout 31 (Z1) Interference suppression capacitor2 (X3/1) Mains terminal strip3 (1K1/1, 2K1/1, 3K1/1) Heating relay4 (X1/1) Payment system soc

Page 12 - B-2 DTD no. 521-7135

This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.2005, DE_en

Page 13 - C Technical Data

12 (A2) Door lock13 (C5) Capacitor - Drum drive14 (M5) Motor - Air flow and drum drive15 (S32) Safety switch - Finger protection16 (1R30) Drying air N

Page 14 - C-2 DTD no. 521-7135

PT 5136xLayout 41 (Z1) Interference suppression capacitor2 (X3/1) Mains terminal strip3 (1K1/1, 2K1/1, 3K1/1) Heating relay4 (X1/1) Payment system soc

Page 15 - PT 7135 C

12 (A2) Door lock13 (C5) Capacitor - Drum drive14 (M5) Motor - Air flow and drum drive15 (1R30) Drying air NTC temperature sensor - Fill ring16 (R1, R

Page 16

020 DoorxDescriptive Technical DocumentationDTD no. 521-7135 020-114.10.2005, DE_en This information should not be duplicated or passed on without Mie

Page 17 - PT 5135 C

2 Function2.1 Door lock (A2)Door release via Bowden cable.An open door is registered via a microswitch in the door lock.Microswitch in door lock (A2):

Page 18

030 Drum, bearing, sensors, heater bankxDescriptive Technical DocumentationDTD no. 521-7135 030-114.10.2005, DE_en This information should not be dupl

Page 19

1 Technical DataHeater bank (R1, R2, R3) Condenser dryer Vented dryerHeater rating with 230 Vconnection3-filament, 2-phase 3-filament, 3-phase1.94 kW

Page 20

Temperature (°C) Resistance (kΩ)190 0.852200 0.710Table 2: NTC temperature sensor - Heater bank (2R30) - Resistance valuesTemperature (°C) Resistance

Page 21

2 Function2.1 Heating control (R1, R2, R3)Safety features:If the fill ring temperature sensor (1R30) is defective, the heating is not activated.The he

Page 22

2.5 Light - Drum (H3/6)Lighting is time-controlled. It is switched on approx. 1 s after the door is opened.Switch off delay: 5 min.When the door is cl

Page 23 - 020 Door

ContentsGeneral InformationA Warning and Safety InstructionsB Modification HistoryC Technical DataD Layout of Electrical ComponentsFunction Groups020

Page 24 - 2 Function

Descriptive Technical Documentation030-6 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights res

Page 25 - DTD no. 521-7135 030-1

040 DrivexDescriptive Technical DocumentationDTD no. 521-7135 040-114.10.2005, DE_en This information should not be duplicated or passed on without Mi

Page 26 - 1 Technical Data

1 Technical DataCooling fan flow rate Condenser dryer Vented dryerCooling air 300 m3/ h –Drying air 120 m3/ h 300 m3/ h. With 20 m vent duct> 200 m

Page 27 - DTD no. 521-7135 030-3

2 Function2.1 Motor - Air flow and drum drive (M5)PT 7135 C, PT 5135 CThe motor drives the drum, drying air fan and cooling air fan at the same time.2

Page 28

Descriptive Technical Documentation040-4 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights res

Page 29 - 2.5 Light - Drum (H3/6)

070 Condensate pump (M5)PT 7135 C, PT 5135 CxDescriptive Technical DocumentationDTD no. 521-7135 070-114.10.2005, DE_en This information should not be

Page 30 - 030-6 DTD no. 521-7135

2 Function2.1 Level sensing - Float switch - Condensate (B8/7)Level sensing is via a reed switch.Descriptive Technical Documentation070-2 DTD no. 521-

Page 31 - 040 Drive

080 Fascia panelxDescriptive Technical DocumentationDTD no. 521-7135 080-114.10.2005, DE_en This information should not be duplicated or passed on wit

Page 32

1 Technical DataPT 7135 Cand PT 7136Cottons MinimumironAutomatic Outerwea Shirts Denim ProofingExtra dryNormal + - 2% 0% -2%Normal 0% 2% 0% 2% 0% 2% 0

Page 33

2 Function2.1 Overriding time controlAfter programme start, an overriding time control of approx. 180 min applies to allresidual moisture drying progr

Page 34 - 040-4 DTD no. 521-7135

2.4 Time of day programmable function . . . . . . . . . . . . . . . . . . . . . . . 080-32.5 Extended cooling phase programmable function. . . . . . .

Page 35 - 070 Condensate pump (M5)

2.5 Extended cooling phase programmable functionAn extended cooling phase means that the laundry temperature is lower at theend of the programme.A low

Page 36

2.7 Clean the airways warning modification programmable functionThis function can be used to modify the circumstances under which the Clean theairways

Page 37 - 080 Fascia panel

2.10 Clean heat exchanger programmable functionPT 7135 C, PT 5135 CWith a condenser dryer this warning is shown at intervals and indicates that thehea

Page 38

2.13 Payment system programmable functionThis is used to set the type of payment system. The appropriate operatingprocedure is shown in the display.Fo

Page 39

2.16 Overriding time control modification programmable function withpayment system operationTo reduce the possibility of unauthorised manipulation wit

Page 40

2.19 Warm air timed programme maximum duration settingprogrammable functionThis is used to set the maximum duration of the Warm air timed programme.PT

Page 41

3 Fault Repair3.1 Warning indication: Clean filterPT 7136CauseThis warning is given at certain intervals as a reminder that the filters must becleaned

Page 42 - PT 7135 C, PT 7136

3.2 Warning indication: Clean heat exchangerPT 7135 C, PT 5135 CCauseWith a condenser dryer this warning is shown at intervals and indicates that theh

Page 43

3.3 Warning indication: Adjust the load – The drum is empty or thelaundry too drySymptomThis warning can only be displayed with residual moisture dryi

Page 44

3.4 Demonstration mode activeSymptomA programme start is not possible and the programming and service modescannot be accessed.CauseThe demonstration m

Page 45

4.6 Service mode summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-38090 Electrical components2 Function . . . . . . . . .

Page 46 - 3 Fault Repair

RemedyA Check the condensate pump (M13). Exchange it if necessary.A PT 7135 C and PT 7136: Service mode, see Service mode summary, 080 4.5.A PT 5135 C

Page 47

CauseClean the airways warning shown too early/late.RemedyA The point at which the Clean the airways warning is shown can be adjustedto suit the needs

Page 48

3.8 Fault code F1, heater bank NTC sensor short-circuitedSymptomIn normal operation mode the display shows Technical fault.Programme interruption, coo

Page 49 - 3.4 Demonstration mode active

CauseHeater bank not heating.RemedyA Check the heater bank (R) for short or open circuit.CauseHeating relay (K1).RemedyA Check the heating relay (K1).

Page 50

3.11 Fault code F4, fill ring NTC sensor open-circuitedSymptomIn normal operation mode the display shows Technical fault.Programme interruption, cooli

Page 51

3.13 Fault code F43, model type not programmedCauseIn normal operation mode this fault is not indicated via the display.The selection module (EW) and

Page 52

3.15 Fault code F46, display faultSymptomProgramme interruption, cooling down phase, intermittent buzzer operation.CauseInternal display fault on sele

Page 53

3.17 Fault code F50, motor stationary and heating operates for 5 sSymptomThe motor for air flow and drum drive (M5) is stationary.This fault occurs in

Page 54

CauseAir path clogged.RemedyA Check and clean the air paths.CauseHeater bank not heating.RemedyA Check the heater bank (R1) for short or open circuit.

Page 55

3.19 Fault code F66, air leakage faultSymptomIn normal operation mode the display shows Clean the airways.CauseAir path clogged.Insuf ficient air flow

Page 56

Descriptive Technical Documentation4 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights reserve

Page 57

4 Service4.1 Programming mode summaryPT 7135 C, PT 7136Initial requirementsA Finish or cancel any programme in operation, including the demonstrationm

Page 58

OptionsThe set option is indicated by a V next to it.A Programmable function selection: Turn the multifunction selector switch tomark the desired func

Page 59

xProgrammable function OptionLanguage Language for operating, programming and service modesSort language Select and sort four favourite languages for

Page 60 - 4 Service

Programmable function OptionClean filters warning, vented dryers only,see 080 2.9 Clean filters programmablefunctionOffDisplay after 5 hDisplay after

Page 61

Programmable function OptionOverriding time control modification withpayment system operation, see 080 2.16Overriding time control modificationprogram

Page 62 - 080-26 DTD no. 521-7135

Save and quitxNoteConfirmed programmable options are saved.A Reconnect the fill ring NTC temperature sensor (1R30) plug.4.2 Programming mode summaryPT

Page 63 - DTD no. 521-7135 080-27

The display shows the Service Dept. programmable functions.If the accessing procedure has been unsuccessful, the control automaticallyreverts to the n

Page 64 - 080-28 DTD no. 521-7135

Programmable function OptionResidual moisture level adjustment -Minimum ironThe standard residual moisture levels can be modified to make them up to3

Page 65 - 4.2 Programming mode summary

Programmable function OptionProgramme lock with payment systemoperation after releasing the Start button,see 080 2.17 Programme lockprogrammable funct

Page 66

4.3 Demonstration mode activation / deactivationPT 7135 C, PT 7136Initial requirementsA Finish or cancel any programme in operation.A Open the door.A

Page 67 - DTD no. 521-7135 080-31

A Warning and Safety Instructions1 General informationService and repair work should only be carried out by suitably qualified persons inaccordance wi

Page 68

Save and quitA Demonstration programme deactivation: Repeat the accessing procedure.4.4 Demonstration mode activation / deactivationPT 5135 C, PT 5136

Page 69

xNoteAfter an interruption in the mains supply, the demonstration mode programmebegins again automatically.Save and quitA Demonstration programme deac

Page 70 - PT 5135 C, PT 5136

OptionsA Service function selection: Turn the multifunction selector switch asappropriate.A Service function start and test step advance: Press the mu

Page 71 - 4.5 Service mode summary

Service function Component / Sensor testedComponent activationComponent activation Function tested/Machine responseAll components InactiveDrive/Fan mo

Page 72

Quit (without saving)A Open the door.4.6 Service mode summaryPT 5135 C, PT 5136Initial requirementsA Ensure the machine is installed and connected cor

Page 73 - DTD no. 521-7135 080-37

xNoteThe service mode is switched off automatically 30 min after the last servicefunction has been checked.Service function Component / Sensor testedS

Page 74 - 4.6 Service mode summary

Service function Component / Sensor testedComponent activationComponent activation Function tested/Machine responseAll components InactiveDrive/Fan mo

Page 75 - DTD no. 521-7135 080-39

Service function Component / Sensor testedControls Display / LED test All display points flash at the same timeAlle LEDs and the illuminated switch su

Page 76 - 080-40 DTD no. 521-7135

Descriptive Technical Documentation080-42 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights re

Page 77 - DTD no. 521-7135 080-41

090 Electrical componentsxDescriptive Technical DocumentationDTD no. 521-7135 090-114.10.2005, DE_en This information should not be duplicated or pass

Page 78 - 080-42 DTD no. 521-7135

2 Risk of injury due to sharp edgesThere may be a risk of injury due to sharp edges.Protective gloves should be worn and the edge protection, Mat. no.

Page 79

2 Function2.1 Mains terminal strip (X3/1)PT 7136, PT 5136Depending on the country version, the mains terminal strip (X3/1) has a 4-/5-poleconnection c

Page 80

2.4 Central control via RS 232 interface with 9-pole plugPT 7135 C, PT 7136Possible to use one central control/payment system.Control data can be read

Page 81 - DTD no. 521-7135 090-3

4 Service4.1 Fitting payment system on machine lidA Remove the machine lid.xFig. 1Warning!When drilling through the machine lid, take care to not dril

Page 82

4.2 Payment system (programme operation)xNoteThe instructions given in the documentation provided with the payment systemmust be followed.Fig. 3A Open

Page 83

4.3 Payment system (timed operation)xNoteThe instructions given in the documentation provided with the payment systemmust be followed.Warning!The conn

Page 84

A Set the tumble dryer payment system programmable option to Timedoperation.A PT 7135 C and PT 7136: For Service Dept. programming mode seeProgramming

Page 85

xFig. 5Fig. 6A Unscrew and remove the mains connection box lid. Loosen the cable strainrelief.A Pass the data cable through the casing opening for the

Page 86

A At the payment system socket (X1/1), cut either through the wire bridge 1W14between pins 1 and 2 or the wire bridge 2W14 between pins 3 and 5 asdesi

Page 87

Descriptive Technical Documentation090-10 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights re

Page 88 - 090-10 DTD no. 521-7135

3 Electrical connection via plug connectorIt is always recommended to make electrical connection via a plug and socket sothat electrical safety checks