Remedy
A Check the condensate pump (M13). Exchange it if necessary.
A PT 7135 C and PT 7136: Service mode, see Service mode summary, 080 4.5.
A PT 5135 C and PT 5136: Service mode, see Service mode summary, 080 4.6.
Cause
The condensate drainage path is blocked.
Remedy
A Check the drainage path for blockages. Repair as necessary.
3.6 Fault indication: Clean the airways
Symptom
The programme continues normally or is interrupted.
The fault is indicated at the end of the cooling down phase.
The fault is saved in the fault memory, see Fault code F66, air leakage fault, 080
3.19.
PT 7135 C and PT 7136: This warning is cancelled when the door is opened.
Cause
Air paths are clogged.
Insuf ficient air flow registered, see 080 2.3 Insufficient air flow measurement.
Remedy
x
Note
Check and clean the filters regularly, see the operating instructions.
A Clean the fluff filters in the door cap and door fill ring.
A Condenser dryer: Remove the heat exchanger and clean it.
A Check and clean the air paths.
Descriptive Technical Documentation
080-14 DTD no. 521-7135
This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.2005, DE_en