2 Function
2.1 Mains terminal strip (X3/1)
PT 7136, PT 5136
Depending on the country version, the mains terminal strip (X3/1) has a 4-/5-pole
connection cable with strain relief.
2.2 Payment system socket (X1/1)
x
Payment system socket (X1/1) - Tumble dryer side Potential Pin
Voltage supply switched by tumble dr yer (ready for operation
signal)
L` 1
Start permitted by payment system L` 2
Voltage supply direct for payment system N 3
Voltage supply direct for payment system L 4
Neutral switched by payment system - Time unit N` 5
Direct earth conductor PE 6
Start reset signal / Time stop / Programme end signal L` 7
Table 1: Payment system socket (X1/1) pin allocation
2.3 Payment system
The tumble dryer is pre-fitted with the requirements for operation in conjunction
with a payment system.
Payment system (programme operation):
The payment system provides the machine with a start permitted signal. After
the programme has been started, it continues without further influence from the
payment system.
For further details, see Payment system (programme operation), 090 4.2.
Payment system (timed operation):
The payment system provides the machine with a constant operation permitted
signal throughout the period of timed operation that has been purchased.
The programme continues so long as the signal is provided.
If the signal is interrupted, the programme and time left are stopped and the
machine components are switched off.
For further details, see Payment system (timed operation), 090 4.3.
Descriptive Technical Documentation
090-2 DTD no. 521-7135
This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.2005, DE_en