3.4 Demonstration mode active
Symptom
A programme start is not possible and the programming and service modes
cannot be accessed.
Cause
The demonstration mode is active.
Remedy
A PT 7135 C and PT 7136: Demonstration mode deactivation, see
Demonstration mode activation / deactivation, 080 4.3.
A PT 5135 C and PT 5136: Demonstration mode deactivation, see
Demonstration mode activation / deactivation, 080 4.4.
3.5 Fault indication: Drain fault Check the drain path
Symptom
Applicable to condenser dryer only.
The programme is cancelled, a cooling phase is started and the buzzer sounds
intermittently.
This warning is cancelled when the door is opened.
Cause
Float switch - Condensate (B8/7) in the condensate pump housing is defective
(shor t-circuited).
Remedy
A Check the float switch - Condensate (B8/7). Exchange it if necessary.
A PT 7135 C and PT 7136: Service mode, see Service mode summary, 080 4.5.
A PT 5135 C and PT 5136: Service mode, see Service mode summary, 080 4.6.
Cause
Condensate pump (M13) defective.
Descriptive Technical Documentation
DTD no. 521-7135 080-13
14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.