2.4 Time of day programmable function . . . . . . . . . . . . . . . . . . . . . . . 080-3
2.5 Extended cooling phase programmable function. . . . . . . . . . . . . 080-4
2.6 Residual moisture level adjustment programmable function. . . . 080-4
2.7 Clean the airways warning modification programmable
function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-5
2.8 Automatic programmable function. . . . . . . . . . . . . . . . . . . . . . . . 080-5
2.9 Clean filters programmable function . . . . . . . . . . . . . . . . . . . . . . 080-5
2.10 Clean heat exchanger programmable function . . . . . . . . . . . . . 080-6
2.11 Residual moisture level display programmable function . . . . . . . 080-6
2.12 Cool air free programmable function, with payment system
operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-6
2.13 Payment system programmable function . . . . . . . . . . . . . . . . . . . 080-7
2.14 Operator code programmable function . . . . . . . . . . . . . . . . . . . . . 080-7
2.15 Signal to payment system socket (X1/1) pin 7 programmable
function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-7
2.16 Overriding time control modification programmable function
with payment system operation. . . . . . . . . . . . . . . . . . . . . . . . . . . 080-8
2.17 Programme lock programmable function with payment system
operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-8
2.18 Cool air timed programme maximum duration setting
programmable function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-8
2.19 Warm air timed programme maximum duration setting
programmable function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-9
2.20 Delay start programmable function . . . . . . . . . . . . . . . . . . . . . . . . 080-9
2.21 Language programmable function . . . . . . . . . . . . . . . . . . . . . . . . 080-9
2.22 Standard settings programmable function . . . . . . . . . . . . . . . . . . 080-9
3 Fault Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-10
3.1 Warning indication: Clean filter . . . . . . . . . . . . . . . . . . . . . . . . . . 080-10
3.2 Warning indication: Clean heat exchanger. . . . . . . . . . . . . . . . . 080-11
3.3 Warning indication: Adjust the load – The drum is empty or the
laundry too dry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-12
3.4 Demonstration mode active. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-13
3.5 Fault indication: Drain fault – Check the drain path . . . . . . . . . . 080-13
3.6 Fault indication: Clean the airways . . . . . . . . . . . . . . . . . . . . . . . 080-14
3.7 Fault indication: Technical fault . . . . . . . . . . . . . . . . . . . . . . . . . . 080-15
3.8 Fault code F1, heater bank NTC sensor short-circuited . . . . . . . 080-16
3.9 Fault code F2, heater bank NTC sensor open-circuited . . . . . . . 080-16
3.10 Fault code F3, fill ring NTC sensor short-circuited . . . . . . . . . . . . 080-17
3.11 Fault code F4, fill ring NTC sensor open-circuited . . . . . . . . . . . . 080-18
3.12 Fault code F41, faulty EEPROM / data fault . . . . . . . . . . . . . . . . . 080-18
3.13 Fault code F43, model type not programmed. . . . . . . . . . . . . . . . 080-19
3.14 Fault code F45, faulty flash RAM/ data fault. . . . . . . . . . . . . . . . . 080-19
3.15 Fault code F46, display fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-20
3.16 Fault code F47, communication fault between selection module
(EW) and power-programme module (ELP) . . . . . . . . . . . . . . . . . 080-20
3.17 Fault code F50, motor stationary and heating operates for 5 s . . 080-21
3.18 Fault code F55, overriding time limit exceeded (approx. 180
min) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-21
3.19 Fault code F66, air leakage fault . . . . . . . . . . . . . . . . . . . . . . . . . . 080-23
4 Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-24
4.1 Programming mode summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-24
4.2 Programming mode summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-29
4.3 Demonstration mode activation / deactivation . . . . . . . . . . . . . . . 080-33
4.4 Demonstration mode activation / deactivation . . . . . . . . . . . . . . . 080-34
4.5 Service mode summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-35
Descriptive Technical Documentation
2 DTD no. 521-7135
This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.2005, DE_en
Comments to this Manuals