3.13 Fault code F43, model type not programmed
Cause
In normal operation mode this fault is not indicated via the display.
The selection module (EW) and power-programme module (ELP) do not match.
Remedy
A Check the Mat. nos. to verify that the correct selection module (EW) and
power-programme module (ELP) are fitted.
3.14 Fault code F45, faulty flash RAM/ data fault
Symptom
In normal operation mode the display shows Technical fault.
Programme interruption, cooling down phase, intermittent buzzer operation.
Cause
Faulty flash RAM/ data fault.
Remedy
A Check the Mat. nos. to verify that the correct selection module (EW) and
power-programme module (ELP) are fitted.
A Reset all programmable functions to standard settings. Then modify the
desired programmable functions.
A Exchange the power-programme module (ELP).
Descriptive Technical Documentation
DTD no. 521-7135 080-19
14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.