Before connecting the appliance,
ensure that it has not been
damaged in any way. Do not use a
damaged appliance.
The appliance is supplied with a mains
cable and moulded plug ready for
connection to an AC single phase
220-240 V 50 Hz supply.
Fuse protection is to be conducted as
follows: Connection to an earthed
power socket, protected with 10 A-L
automat or fuse 10 A.
Connection must only be made via a
suitable switched socket. The electrical
system must comply with VDE0100.
The appliance should be positioned so
that the plug is accessible.
Connection should be made via a
suitable switched socket, or via a
suitable isolator, which complies with
national and local safety regulations,
and the on/off switch should be easily
accessible after the appliance has
been installed. If it is installed via an
isolator switch, connection must be
carried out by an electrician.
When switched off, there must be an
all-pole contact gap of 3 mm in the
switch (including switch, fuses and
relays).
The voltage, rated load and fuse rating
are given on the data plate situated at
the front of the oven interior. Please
ensure these match the household
mains supply.
If the supply cord is damaged, it must
be replaced by a Miele approved ser
-
vice technician to avoid a hazard.
Do not connect the machine to an
inverter such as those used with an
autonomous energy source e.g. Solar
power. When switched on, peak loads
in the system can cause the safety
switch off mechanism to be triggered.
This can damage the electronic unit.
The machine must not be used with
so-called Energy saving devices
either. These reduce the amount of
energy supplied to the machine,
causing it to overheat.